Show simple item record

dc.contributor.authorWang, Pei-Jiang
dc.contributor.authorBerti, Francesca
dc.contributor.authorAntonini, Luca
dc.contributor.authorNezami, Farhad R
dc.contributor.authorPetrini, Lorenza
dc.contributor.authorMigliavacca, Francesco
dc.contributor.authorEdelman, Elazer R
dc.date.accessioned2021-11-01T14:33:17Z
dc.date.available2021-11-01T14:33:17Z
dc.date.issued2020-10-29
dc.identifier.urihttps://hdl.handle.net/1721.1/136774
dc.description.abstractAbstract Bioresorbable vascular scaffolds were considered the fourth generation of endovascular implants deemed to revolutionize cardiovascular interventions. Yet, unexpected high risk of scaffold thrombosis and post-procedural myocardial infractions quenched the early enthusiasm and highlighted the gap between benchtop predictions and clinical observations. To better understand scaffold behavior in the mechanical environment of vessels, animal, and benchtop tests with multimodal loading environment were conducted using industrial standard scaffolds. Finite element analysis was also performed to study the relationship among structural failure, scaffold design, and load types. We identified that applying the combination of bending, axial compression, and torsion better reflects incidence observed in-vivo, far more than tranditional single mode loads. Predication of fracture locations is also more accurate when at least bending and axial compression are applied during benchtop tests (>60% fractures at connected peak). These structural failures may be initiated by implantation-induced microstructural damages and worsened by cyclic loads from the beating heart. Ignoring the multi-modal loading environment in benchtop fatigue tests and computational platforms can lead to undetected potential design defects, calling for redefining consensus evaluation strategies for scaffold performance. With the robust evaluation strategy presented herein, which exploits the results of in-vivo, in-vitro and in-silico investigations, we may be able to compare alternative designs of prototypes at the early stages of device development and optimize the performance of endovascular implants according to patients-specific vessel dynamics and lesion configurations in the future.en_US
dc.publisherSpringer International Publishingen_US
dc.relation.isversionofhttps://doi.org/10.1007/s10439-020-02673-zen_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourceSpringer International Publishingen_US
dc.titleMultimodal Loading Environment Predicts Bioresorbable Vascular Scaffolds’ Durabilityen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Institute for Medical Engineering & Science
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2021-04-21T03:35:30Z
dc.language.rfc3066en
dc.rights.holderBiomedical Engineering Society
dspace.embargo.termsY
dspace.date.submission2021-04-21T03:35:30Z
mit.licenseOPEN_ACCESS_POLICY
mit.metadata.statusAuthority Work and Publication Information Needed


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record