Status and prospects for CUORE
Author(s)
Canonica, L; Alduino, C; Alfonso, K; Artusa, D R; Avignone, F T; Azzolini, O; Banks, T I; Bari, G; Beeman, J W; Bellini, F; Bersani, A; Biassoni, M; Branca, A; Brofferio, C; Bucci, C; Camacho, A; Caminata, A; Cao, X G; Capelli, S; Cappelli, L; Carbone, L; Cardani, L; Carniti, P; Casali, N; Cassina, L; Chiesa, D; Chott, N; Clemenza, M; Copello, S; Cosmelli, C; Cremonesi, O; Creswick, R J; Cushman, J S; D’Addabbo, A; Dafinei, I; Davis, C J; Dell’Oro, S; Deninno, M M; Di Domizio, S; Di Vacri, M L; Drobizhev, A; Fang, D Q; Faverzani, M; Fernandes, G; Ferri, E; Ferroni, F; Fiorini, E; Franceschi, M A; Freedman, S J; Fujikawa, B K; Giachero, A; Gironi, L; Giuliani, A; Gladstone, L; Gorla, P; Gotti, C; Gutierrez, T D; Haller, E E; Han, K; Hansen, E; Heeger, K M; Hennings-Yeomans, R; Hickerson, K P; Huang, H Z; Kadel, R; Keppel, G; Kolomensky, Yu G; Leder, A; Ligi, C; Lim, K E; Liu, X; Ma, Y G; Maino, M; Marini, L; Martinez, M; Maruyama, R H; Mei, Y; Moggi, N; Morganti, S; Mosteiro, P J; Napolitano, T; Nones, C; Norman, E B; Novati, V; Nucciotti, A; O’Donnell, T; Orio, F; Ouellet, J L; Pagliarone, C E; Pallavicini, M; Palmieri, V; Pattavina, L; Pavan, M; Pessina, G; Pettinacci, V; Piperno, G; Pirro, S; Pozzi, S; Previtali, E; Rosenfeld, C; Rusconi, C; Sangiorgio, S; Santone, D; Scielzo, N D; Singh, V; Sisti, M; Smith, A R; Taffarello, L; Tenconi, M; Terranova, F; Tomei, C; Trentalange, S; Vignati, M; Wagaarachchi, S L; Wang, B S; Wang, H W; Wilson, J; Winslow, L A; Wise, T; Woodcraft, A; Zanotti, L; Zhang, G Q; Zhu, B X; Zimmermann, S; Zucchelli, S; ... Show more Show less
DownloadPublished version (527.9Kb)
Publisher with Creative Commons License
Publisher with Creative Commons License
Creative Commons Attribution
Terms of use
Metadata
Show full item recordAbstract
© Published under licence by IOP Publishing Ltd. CUORE is a cryogenic detector consisting of 988 TeO 2 crystals, 750 g each, and will be operated at a temperature of ∼10 mK, to search for neutrinoless double beta decay (0νββ) of 130 Te. The detector, in the final stages of construction at the Laboratori Nazionali del Gran Sasso (Italy), will start its operations in 2016. CUORE-0, its pilot experiment, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach. CUORE-0 also made the most precise measurement of the 2νββ decay. The expected sensitivity of CUORE to the 0νββ 130 Te half-life is 9 •10 25 y, for 5 years of data taking. Here, we report the most recent results of CUORE-0, their implications for CUORE, and the current status of the CUORE experiment.
Date issued
2017-09Department
Massachusetts Institute of Technology. Department of PhysicsPublisher
IOP Publishing
Citation
Canonica, L, Alduino, C, Alfonso, K, Artusa, D R, Avignone, F T et al. 2017. "Status and prospects for CUORE." 888.
Version: Final published version
ISSN
1742-6588
1742-6596