Notice

This is not the latest version of this item. The latest version can be found at:https://dspace.mit.edu/handle/1721.1/138087.2

Show simple item record

dc.contributor.authorLahlou, Radia
dc.contributor.authorArmstrong, Peter R.
dc.contributor.authorCalvet, Nicolas
dc.contributor.authorSlocum, Alexander H.
dc.contributor.authorShamim, Tariq
dc.date.accessioned2021-11-09T21:51:13Z
dc.date.available2021-11-09T21:51:13Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/1721.1/138087
dc.description.abstract© 2018 Author(s). Three dimensional secondary concentrators are exposed to high radiation fluxes, part of which is absorbed by the reflecting material, leading to elevated wall temperatures which may cause reflectance degradation and mechanical distortion. Temperature monitoring and thermal management is required. Existing 3D secondary concentrators used in beam-up or beam-down tower plants use water-based convective cooling for which failures and leaks have been reported. The present work tested two alternative non-liquid-based cooling strategies: enhanced radiative cooling using a high-emissivity paint and forced-air convective cooling. The concentrator under no cooling enhancement reached temperatures above the acceptable limit, indicating the need for better cooling. Forced-convective cooling had the most noticeable effect and proved sufficient for the considered testing conditions. The impact of radiative cooling enhancement was lower in the considered incident flux conditions, as the initial temperature without enhancement was relatively low.en_US
dc.language.isoen
dc.publisherAIP Publishingen_US
dc.relation.isversionof10.1063/1.5067171en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceOther repositoryen_US
dc.titleTesting of a Secondary Concentrator Integrated with a Beam-Down Tower System under Non-liquid Cooling Strategiesen_US
dc.typeArticleen_US
dc.identifier.citationLahlou, Radia, Armstrong, Peter R., Calvet, Nicolas, Slocum, Alexander H. and Shamim, Tariq. 2018. "Testing of a Secondary Concentrator Integrated with a Beam-Down Tower System under Non-liquid Cooling Strategies."
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2019-09-20T11:53:53Z
dspace.date.submission2019-09-20T11:53:55Z
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

VersionItemDateSummary

*Selected version