Design of a Multi-Degree-of-Freedom Traction and Stabilization Device for Open Reduction and Internal Fixation of Distal Radius Fractures

Author(s)
Oeding, J; Bockman, S; Chiu, H; Hua, C; Connor, J; Slocum, A; ... Show more Show less
Thumbnail
DownloadPublished version (1.417Mb)
Publisher Policy

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
<jats:title>Abstract</jats:title> <jats:p>Open reduction and internal fixation (ORIF) is a surgical procedure performed with the objectives of restoring normal alignment and providing stability to broken bone fragments after a fracture. This procedure is increasingly used to treat fractures of the distal end of the radius. Reduction of the fracture into correct alignment is often achieved by the surgeon pulling and manipulating the hand while looking at real-time x-rays, and frequently requires large forces to distract impacted fragments from proximal bone. This can make the task of simultaneously aligning the fracture fragments and placing hardware to secure fragments into the correct position particularly challenging for surgeons. This study presents the design and preliminary testing of a multi-degree-of-freedom (DOF) device capable of performing both distraction and reduction of fractured bone fragments using a traction splint mechanism with locking joints that results in significantly reduced effort and greater accuracy in performing ORIF procedures on distal radius fractures. Quantitative force testing found an 80% reduction in the maximum force required to create needed traction, while qualitative tests with a hand surgeon found the device’s ability to reduce and stabilize bone fragments while hardware is secured to be more intuitive and less obstructive than existing techniques.</jats:p>
Date issued
2021
URI
https://hdl.handle.net/1721.1/139671
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
2021 Design of Medical Devices Conference
Publisher
ASME International
Citation
Oeding, J, Bockman, S, Chiu, H, Hua, C, Connor, J et al. 2021. "Design of a Multi-Degree-of-Freedom Traction and Stabilization Device for Open Reduction and Internal Fixation of Distal Radius Fractures." 2021 Design of Medical Devices Conference.
Version: Final published version

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.