Show simple item record

dc.contributor.authorChen, Siyu
dc.contributor.authorPotsaid, Benjamin
dc.contributor.authorLi, Yan
dc.contributor.authorLin, Junhong
dc.contributor.authorHwang, Yunchan
dc.contributor.authorMoult, Eric M
dc.contributor.authorZhang, Jason
dc.contributor.authorHuang, David
dc.contributor.authorFujimoto, James G
dc.date.accessioned2022-06-22T18:26:04Z
dc.date.available2022-06-22T18:26:04Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/1721.1/143547
dc.description.abstract<jats:title>Abstract</jats:title><jats:p>This study reports the development of prototype swept-source optical coherence tomography (SS-OCT) technology for imaging the anterior eye. Advances in vertical-cavity surface-emitting laser (VCSEL) light sources, signal processing, optics and mechanical designs, enable a unique combination of high speed, long range, and deep penetration that addresses the challenges of anterior eye imaging. We demonstrate SS-OCT with a 325 kHz A-scan rate, 12.2 µm axial resolution (in air), and 15.5 mm depth range (in air) at 1310 nm wavelength. The ultrahigh 325 kHz A-scan rate not only facilitates biometry measurements by minimizing acquisition time and thus reducing motion, but also enables volumetric OCT for comprehensive structural analysis and OCT angiography (OCTA) for visualizing vasculature. The 15.5 mm (~ 11.6 mm in tissue) depth range spans all optical surfaces from the anterior cornea to the posterior lens capsule. The 1310 nm wavelength range enables structural OCT and OCTA deep in the sclera and through the iris. Achieving high speed and long range requires linearizing the VCSEL wavenumber sweep to efficiently utilize analog-to-digital conversion bandwidth. Dual channel recording of the OCT and calibration interferometer fringe signals, as well as sweep to sweep wavenumber compensation, is used to achieve invariant 12.2 µm (~ 9.1 µm in tissue) axial resolution and optimum point spread function throughout the depth range. Dynamic focusing using a tunable liquid lens extends the effective depth of field while preserving the lateral resolution. Improved optical and mechanical design, including parallax “split view” iris cameras and stable, ergonomic patient interface, facilitates accurate instrument positioning, reduces patient motion, and leads to improved imaging data yield and measurement accuracy. We present structural and angiographic OCT images of the anterior eye, demonstrating the unique imaging capabilities using representative scanning protocols which may be relevant to future research and clinical applications.</jats:p>en_US
dc.language.isoen
dc.publisherSpringer Science and Business Media LLCen_US
dc.relation.isversionof10.1038/S41598-022-04784-0en_US
dc.rightsCreative Commons Attribution 4.0 International licenseen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en_US
dc.sourceScientific Reportsen_US
dc.titleHigh speed, long range, deep penetration swept source OCT for structural and angiographic imaging of the anterior eyeen_US
dc.typeArticleen_US
dc.identifier.citationChen, Siyu, Potsaid, Benjamin, Li, Yan, Lin, Junhong, Hwang, Yunchan et al. 2022. "High speed, long range, deep penetration swept source OCT for structural and angiographic imaging of the anterior eye." Scientific Reports, 12 (1).
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.contributor.departmentMassachusetts Institute of Technology. Research Laboratory of Electronics
dc.contributor.departmentHarvard University--MIT Division of Health Sciences and Technology
dc.relation.journalScientific Reportsen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2022-06-22T18:18:46Z
dspace.orderedauthorsChen, S; Potsaid, B; Li, Y; Lin, J; Hwang, Y; Moult, EM; Zhang, J; Huang, D; Fujimoto, JGen_US
dspace.date.submission2022-06-22T18:18:51Z
mit.journal.volume12en_US
mit.journal.issue1en_US
mit.licensePUBLISHER_CC
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record