Show simple item record

dc.contributor.authorAbulnaga, S Mazdak
dc.contributor.authorTurk, Esra Abaci
dc.contributor.authorBessmeltsev, Mikhail
dc.contributor.authorGrant, P Ellen
dc.contributor.authorSolomon, Justin
dc.contributor.authorGolland, Polina
dc.date.accessioned2022-06-28T18:38:28Z
dc.date.available2022-06-28T18:38:28Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/1721.1/143586
dc.description.abstractWe present a volumetric mesh-based algorithm for parameterizing the placenta to a flattened template to enable effective visualization of local anatomy and function. MRI shows potential as a research tool as it provides signals directly related to placental function. However, due to the curved and highly variable in vivo shape of the placenta, interpreting and visualizing these images is difficult. We address interpretation challenges by mapping the placenta so that it resembles the familiar ex vivo shape. We formulate the parameterization as an optimization problem for mapping the placental shape represented by a volumetric mesh to a flattened template. We employ the symmetric Dirichlet energy to control local distortion throughout the volume. Local injectivity in the mapping is enforced by a constrained line search during the gradient descent optimization. We validate our method using a research study of 111 placental shapes extracted from BOLD MRI images. Our mapping achieves sub-voxel accuracy in matching the template while maintaining low distortion throughout the volume. We demonstrate how the resulting flattening of the placenta improves visualization of anatomy and function. Our code is freely available at https://github.com/mabulnaga/placenta-flattening .en_US
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en_US
dc.relation.isversionof10.1109/TMI.2021.3128743en_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourcearXiven_US
dc.titleVolumetric Parameterization of the Placenta to a Flattened Templateen_US
dc.typeArticleen_US
dc.identifier.citationAbulnaga, S Mazdak, Turk, Esra Abaci, Bessmeltsev, Mikhail, Grant, P Ellen, Solomon, Justin et al. 2022. "Volumetric Parameterization of the Placenta to a Flattened Template." IEEE Transactions on Medical Imaging, 41 (4).
dc.contributor.departmentMassachusetts Institute of Technology. Computer Science and Artificial Intelligence Laboratory
dc.relation.journalIEEE Transactions on Medical Imagingen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2022-06-28T18:22:51Z
dspace.orderedauthorsAbulnaga, SM; Turk, EA; Bessmeltsev, M; Grant, PE; Solomon, J; Golland, Pen_US
dspace.date.submission2022-06-28T18:22:57Z
mit.journal.volume41en_US
mit.journal.issue4en_US
mit.licenseOPEN_ACCESS_POLICY
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record