dc.description.abstractIn this work, we have studied how the vertical illuminance of the human eye position, illuminance of the horizontal work surface, and the brightness of the computer screen in the office space lighting are correlated under an energy-saving environment. This investigation was conducted in a full-scale laboratory that simulates an office space with 20 adults. It was found that when the indoor ambient lighting illuminance changes, the vertical illuminance of the subject’s eye position is affected accordingly, and the two factors are strongly correlated. On the other hand, when the surrounding environment is brighter and the vertical illuminance increases, the illuminance of the horizontal working surface adjusted by the subject during the visual display terminal (VDT) operation is significantly reduced. The horizontal illuminance value can even be lower than the value frequently employed in various countries around the world, since the computer screen brightness will be adjusted accordingly. Therefore, in an energy-saving environment, the illuminance of the horizontal working surface and the brightness of the computer screen adjusted by the users will vary with the ambient lighting. Especially in the current mainstream VDT operating environment and within a certain range of conditions, the interior setting can be lower than the current horizontal illuminance benchmark for additional energy conservation.en_US
dc.publisherMultidisciplinary Digital Publishing Instituteen_US
dc.relation.isversionofhttp://dx.doi.org/10.3390/en16031317en_US
dc.rightsCreative Commons Attributionen_US
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/en_US
dc.sourceMultidisciplinary Digital Publishing Instituteen_US
dc.titleStrategies on Visual Display Terminal Lighting in Office Space under Energy-Saving Environmenten_US
dc.typeArticleen_US
dc.identifier.citationEnergies 16 (3): 1317 (2023)en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Chemical Engineering
dc.identifier.mitlicensePUBLISHER_CC
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2023-02-10T14:28:24Z
dspace.date.submission2023-02-10T14:28:24Z
mit.licensePUBLISHER_CC
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record