Simultaneous transverse loading and axial strain for REBCO cable tests in the SULTAN facility

Author(s)
Fry, Vincent; Estrada, Jose; Michael, Philip C; Salazar, Erica E; Vieira, Rui F; Hartwig, Zachary S; ... Show more Show less
Thumbnail
DownloadAccepted version (782.5Kb)
Open Access Policy

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
<jats:title>Abstract</jats:title> <jats:p>We present the design and first results of an assembly that enables rare earth barium copper oxide (REBCO) superconducting cables—the VIPER cable in this work—to be tested in the SULTAN facility under the simultaneous application of transverse electromechanical loading and axial mechanical strain. The objective is to emulate the loads that a REBCO cable would experience in a three-dimensional coil but in shorter and simpler straight cables, reducing the cost, schedule, and complexity of high-fidelity conductor qualification. The assembly uses two methods for inducing axial strain in the cables. First, hydraulic jacks stretch the assembly and inserted Invar shims lock in up to ∼0.3% axial cable strain on the benchtop at room temperature. Second, the different coefficients of thermal expansion between Invar clamps and the copper cable are exploited to induce an additional ∼0.3% axial strain on the cable when the sample is cooled in the SULTAN test well from room temperature to below 50 K. Finite element analysis modeling shows that the soldered matrix of the VIPER cable transfers approximately 50%–60% of the external cable strain into the REBCO stack. The assembly was successfully employed at SULTAN, enabling two VIPER cables to be cycled 500 times at 382 kN m<jats:sup>−1</jats:sup> transverse electromechanical loads with ∼0.5% mechanical strain on the cable (corresponding to ∼0.3% mechanical strain in the REBCO stacks) demonstrating critical current degradation stabilizing after 30 cycles at less than 5% and providing confidence in VIPER cables under realistic high-field magnet conditions.</jats:p>
Date issued
2022
URI
https://hdl.handle.net/1721.1/148291
Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Journal
Superconductor Science and Technology
Publisher
IOP Publishing
Citation
Fry, Vincent, Estrada, Jose, Michael, Philip C, Salazar, Erica E, Vieira, Rui F et al. 2022. "Simultaneous transverse loading and axial strain for REBCO cable tests in the SULTAN facility." Superconductor Science and Technology, 35 (7).
Version: Author's final manuscript

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.