Show simple item record

dc.contributor.authorChevalier, Samuel C.
dc.contributor.authorVorobev, Petr
dc.contributor.authorTuritsyn, Konstantin
dc.date.accessioned2024-05-29T20:17:05Z
dc.date.available2024-05-29T20:17:05Z
dc.date.issued2018-11
dc.identifier.issn0885-8950
dc.identifier.issn1558-0679
dc.identifier.urihttps://hdl.handle.net/1721.1/155092
dc.description.abstractLocating the sources of forced low-frequency oscillations in power systems is an important problem. A number of proposed methods demonstrate their practical usefulness, but many of them rely on strong modeling assumptions and provide poor performance in certain cases for reasons still not well understood. This paper proposes a systematic method for locating the source of a forced oscillation by considering a generator's response to fluctuations of its terminal voltages and currents. It is shown that a generator can be represented as an effective admittance matrix with respect to low-frequency oscillations, and an explicit form for this matrix, for various generator models, is derived. Furthermore, it is shown that a source generator, in addition to its effective admittance, is characterized by the presence of an effective current source, thus giving a natural qualitative distinction between source and nonsource generators. Detailed descriptions are given of a source detection procedure based on this developed representation, and the method's effectiveness is confirmed by simulations on the recommended testbeds (e.g., WECC 179-bus system). This method is free of strong modeling assumptions and is also shown to be robust in the presence of measurement noise and generator parameter uncertainty.en_US
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineersen_US
dc.relation.isversionof10.1109/tpwrs.2018.2834229en_US
dc.rightsCreative Commons Attribution-Noncommercial-ShareAlikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourcearxiven_US
dc.titleUsing Effective Generator Impedance for Forced Oscillation Source Locationen_US
dc.typeArticleen_US
dc.identifier.citationS. C. Chevalier, P. Vorobev and K. Turitsyn, "Using Effective Generator Impedance for Forced Oscillation Source Location," in IEEE Transactions on Power Systems, vol. 33, no. 6, pp. 6264-6277, Nov. 2018.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.relation.journalIEEE Transactions on Power Systemsen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2024-05-29T20:10:33Z
dspace.orderedauthorsChevalier, SC; Vorobev, P; Turitsyn, Ken_US
dspace.date.submission2024-05-29T20:10:35Z
mit.journal.volume33en_US
mit.journal.issue6en_US
mit.licenseOPEN_ACCESS_POLICY
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record