Finite Element Modeling of Abdominal Near‐Infrared Spectroscopy for Infant Splanchnic Oximetry

Author(s)
Emani, Vishnu S; Ozturk, Caglar; Singh, Manisha; Long, Carly; Duffy, Summer; Sen, Danielle Gottlieb; Roche, Ellen T; Baker, Wesley B; ... Show more Show less
Thumbnail
DownloadPublished version (757.2Kb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution https://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Abdominal near-infrared spectroscopy (NIRS) holds promise for early detection of necrotizing enterocolitis and other infantpathologies prior to irreversible injury, but the optimal NIRS sensor design is not well defined. In this study, we develop anddemonstrate a computational method to evaluate NIRS sensor designs for infant splanchnic oximetry. We used a finite element(FE) approach to simulate near-infrared light transport through a 3D model of the infant abdomen constructed from computedtomography (CT) images. The simulations enable the measurement of the contrast-to-noise ratio (CNR) for splanchnic oximetry,given a specific NIRS sensor design. A key design criterion is the sensor's source–detector distance (SDD). We calculated the CNRas a function of SDD for two sensor positions near the umbilicus. Contrast-to-noise was maximal at SDDs between 4 and 5 cm,and comparable between sensor positions. Sensitivity to intestinal tissue also exceeded sensitivity to superficial adipose tissue inthe 4–5 cm range. FE modeling of abdominal NIRS signals provides a means for rapid and thorough evaluation of sensor designsfor infant splanchnic oximetry. By informing optimal NIRS sensor design, the computational methods presented here can im-prove the reliability and applicability of infant splanchnic oximetry.
Date issued
2025-04-15
URI
https://hdl.handle.net/1721.1/162868
Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science; Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
International Journal for Numerical Methods in Biomedical Engineering
Publisher
Wiley
Citation
Emani, V.S., Ozturk, C., Singh, M., Long, C., Duffy, S., Sen, D.G., Roche, E.T. and Baker, W.B. (2025), Finite Element Modeling of Abdominal Near-Infrared Spectroscopy for Infant Splanchnic Oximetry. Int J Numer Meth Biomed Engng, 41: e70035.
Version: Final published version

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.