MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

On‐Patient Temporary Medical Record for Accurate, Time‐Sensitive Information at the Point of Care

Author(s)
Collins, Joe; Han, Jooli; Sarmadi, Morteza; Allison‐Logan, Stephanie; Straeten, Aurelien vander; Perkinson, Collin F; Acolaste, Sarah; Kanelli, Maria; Daristotle, John; Karchin, Ari; Henderson, Mitchell; Cruz, Mache; Artzi, Dolev; Alsaiari, Shahad K; Zhang, Linzixuan; Levy, Lauren; Wood, Lowell; Jing, Lihong; McHugh, Kevin J; Bawendi, Moungi G; Langer, Robert; Jaklenec, Ana; ... Show more Show less
Thumbnail
DownloadPublished version (3.074Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution https://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
Accurate medical recordkeeping is important for personal and public health. Conventional forms of on‐patient medical information, such as medical alert bracelets or finger‐markings, may compromise patient privacy because they are readily visible to other people. Here, the development of an invisible, temporary, and easily deployable on‐patient medical recordkeeping system is reported. Information is stored in unique patterns of spatially distributed near‐infrared (NIR) fluorescent quantum dots (QDs), which are delivered to the skin using dissolvable microneedle arrays. The patterns are invisible to the naked eye but detectable with an infrared camera, which can extract information with >98% accuracy using automated pattern recognition software. By encapsulating NIR QDs in an FDA‐approved biodegradable polymer, biodegradation rates can be tuned so that the encoded medical information can be conveyed in both a spatial and temporal manner, with some components fading within 100 days and others persisting for 6 months. This may be particularly useful for administering a series of vaccinations or treatments by indicating if enough time has passed for the patient to receive the next dose. Importantly, this system contains no personal information, does not require connection to a centralized database, and is not visible to the naked eye, ensuring patient privacy.
Date issued
2024-04-18
URI
https://hdl.handle.net/1721.1/163160
Department
Koch Institute for Integrative Cancer Research at MIT; Massachusetts Institute of Technology. Department of Mechanical Engineering; Harvard University--MIT Division of Health Sciences and Technology; Massachusetts Institute of Technology. Department of Chemistry; Massachusetts Institute of Technology. Department of Chemical Engineering
Journal
Advanced Functional Materials
Publisher
Wiley
Citation
J. Collins, J. Han, M. Sarmadi, S. Allison-Logan, A. vander Straeten, C. F. Perkinson, S. Acolaste, M. Kanelli, J. Daristotle, A. Karchin, M. Henderson, M. Cruz, D. Artzi, S. K. Alsaiari, L. Zhang, L. Levy, L. Wood, L. Jing, K. J. McHugh, M. G. Bawendi, R. Langer, A. Jaklenec, On-Patient Temporary Medical Record for Accurate, Time-Sensitive Information at the Point of Care. Adv. Funct. Mater. 2024, 34, 2311821.
Version: Final published version

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.