1. Reports: Recent submissions
Now showing items 184-186 of 375
-
Development of models for the sodium version of the two-phase three dimensional thermal hydraulics code THERMIT
(MIT Energy Laboratory, 1980-05)Several different models and correlations were developed and incorporated in the sodium version of THERMIT, a thermal- hydraulics code written at MIT for the purpose of analyzing transients under LMFBR conditions. ... -
SERI photovoltaic venture analysis : long term demand estimation
(Massachusetts Institute of Technology. Energy Laboratory., 1978-07)This report presents the results of a sectoral demand analysis for photo- voltaic power systems used in the residential sector single family homes], the service, commercial, and institutional sector [schools] and in ... -
Operational issues involving use of supplementary cooling towers to meet stream temperature standards with application to the Browns Ferry Nuclear Plant
(MIT Energy Laboratory, 1979-01)A mixed mode cooling system is one which operates in either the open, closed, or helper (once-through but with the use of the cooling towers) modes. Such systems may be particularly economical where the need for ...