MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validation of a novel catheter guiding method for the ablative therapy of ventricular tachycardia in a phantom model

Author(s)
Hirschman, Gordon B.; Rosbury, Tamara S.; Armoundas, Antonis A.; Galea, Anna M.; Choppy, Kristen J.; Barley, Maya E.; Cohen, Richard J.; ... Show more Show less
Thumbnail
DownloadBarley-2009-Validation of a Nove.pdf (167.0Kb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Accurate guidance of an ablation catheter is critical in the RF ablation (RFA) of ventricular tachycardia (VT). With current technologies, it is challenging to rapidly and accurately localize the site of origin of an arrhythmia, often restricting treatment to patients with hemodynamically stable arrhythmias. We investigated the effectiveness of a new guidance method, the inverse solution guidance algorithm (ISGA), which is based on a single-equivalent dipole representation of cardiac electrical activity and is suitable for patients with hemodynamically unstable VT. Imaging was performed in homogeneous and inhomogeneous saline-filled torso phantoms in which a catheter tip was guided toward a stationary electrical dipole source over distances of more than 5 cm. Using ISGA, the moving catheter tip was guided to within 0.61 plusmn0.43 and 0.55 plusmn0.39 mm of the stationary source in the homogeneous and inhomogeneous phantoms, respectively. This accuracy was achieved with less than ten movements of the catheter. These results suggest that ISGA has potential to provide accurate and efficient guidance for RFA procedures in the patient population with hemodynamically unstable arrhythmias.
Date issued
2009-04
URI
http://hdl.handle.net/1721.1/52411
Department
Harvard University--MIT Division of Health Sciences and Technology
Journal
IEEE Transactions on Biomedical Engineering
Publisher
Institute of Electrical and Electronics Engineers
Citation
Barley, M.E. et al. “Validation of a Novel Catheter Guiding Method for the Ablative Therapy of Ventricular Tachycardia in a Phantom Model.” Biomedical Engineering, IEEE Transactions on 56.3 (2009): 907-910. © 2009 IEEE
Version: Final published version
ISSN
0018-9294

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.