Show simple item record

dc.contributor.authorSun, Shih-Yu
dc.contributor.authorAnthony, Brian
dc.contributor.authorGilbertson, Matthew W.
dc.date.accessioned2010-09-16T15:19:45Z
dc.date.available2010-09-16T15:19:45Z
dc.date.issued2010-03
dc.date.submitted2010-02
dc.identifier.issn0277-786X
dc.identifier.otherProc. of SPIE Vol. 7629 76290A-1
dc.identifier.urihttp://hdl.handle.net/1721.1/58562
dc.description.abstractTissue deformation in ultrasound imaging poses a challenge to the development of many image registration techniques, including multimodal image fusion, multi-angle compound image and freehand three-dimensional ultrasound. Although deformation correction methods are desired to provide images of uncompressed tissue structure, they have not been well-studied. A novel trajectory-based method to correct a wide range of tissue deformation in ultrasound imaging was developed. In order to characterize tissue deformation under different contact forces, a force sensor provides contact force measurement. Template based image-flow techniques were applied to RF A-lines under different contact forces. A two-dimensional displacement trajectory field was constructed, where pixel coordinates in each scan were plotted against the corresponding contact force. Nonlinear extrapolation algorithms are applied to each trajectory to relocate the corresponding pixel to where it would have been had there been no contact, thereby correcting tissue deformation in the images. This method was validated by using a combination of FEM deformation and ultrasound simulation. It was shown that deformation of the simulated pathological tissue could be corrected. Furthermore, nonlinear polynomial regression was found to give better estimates, than linear regression, when large deformation was present. Estimation accuracy was not improved significantly for a polynomial regression larger than second order.en_US
dc.description.sponsorshipSingapore-MIT Allianceen_US
dc.description.sponsorshipTerason (Firm)en_US
dc.language.isoen_US
dc.publisherSPIEen_US
dc.relation.isversionofhttp://dx.doi.org/10.1117/12.844184en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSPIEen_US
dc.titleTrajectory-based Deformation Correction in Ultrasound Imagesen_US
dc.typeArticleen_US
dc.identifier.citationSun, Shih-Yu, Brian W. Anthony, and Matthew W. Gilbertson. “Trajectory-based deformation correction in ultrasound images.” Medical Imaging 2010: Ultrasonic Imaging, Tomography, and Therapy. Ed. Jan D'hooge & Stephen A. McAleavey. San Diego, California, USA: SPIE, 2010. 76290A-9. © 2010 SPIE.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Scienceen_US
dc.contributor.departmentMassachusetts Institute of Technology. Laboratory for Manufacturing and Productivityen_US
dc.contributor.approverAnthony, Brian
dc.contributor.mitauthorSun, Shih-Yu
dc.contributor.mitauthorAnthony, Brian
dc.contributor.mitauthorGilbertson, Matthew W.
dc.relation.journalProceedings of the Society of Photo-optical Instrumentation Engineersen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsSun, Shih-Yu; Anthony, Brian W.; Gilbertson, Matthew W.en
mit.licensePUBLISHER_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record