| dc.contributor.author | Yip, Marcus | |
| dc.contributor.author | He, David Da | |
| dc.contributor.author | Winokur, Eric S. | |
| dc.contributor.author | Balderrama, Amanda Gaudreau | |
| dc.contributor.author | Sheridan, Robert | |
| dc.contributor.author | Ma, Hongshen | |
| dc.date.accessioned | 2010-09-30T15:48:41Z | |
| dc.date.available | 2010-09-30T15:48:41Z | |
| dc.date.issued | 2009-11 | |
| dc.date.submitted | 2009-09 | |
| dc.identifier.isbn | 978-1-4244-3296-7 | |
| dc.identifier.issn | 1557-170X | |
| dc.identifier.uri | http://hdl.handle.net/1721.1/58788 | |
| dc.description.abstract | Pressure ulcers are painful sores that arise from prolonged exposure to high pressure points, which restricts blood flow and leads to tissue necrosis. This is a common occurrence among patients with impaired mobility, diabetics and the elderly. In this work, a flexible pressure monitoring system for pressure ulcer prevention has been developed. The prototype consists of 99 capacitive pressure sensors on a 17-cm times 22-cm sheet which is flexible in two dimensions. Due to its low cost, the sensor sheet can be disconnected from the reusable electronics and be disposed of after use, suitable for a clinical setting. Each sensor has a resolution of better than 2-mmHg and a range of 50-mmHg and offset is calibrated in software. Realtime pressure data is displayed on a computer. A maximum sampling rate of 12-Hz allows for continuous monitoring of pressure points. | en_US |
| dc.description.sponsorship | Center for Integration of Medicine and Innovative Technology | en_US |
| dc.language.iso | en_US | |
| dc.publisher | Institute of Electrical and Electronics Engineers | en_US |
| dc.relation.isversionof | http://dx.doi.org/10.1109/IEMBS.2009.5333964 | en_US |
| dc.rights | Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. | en_US |
| dc.source | IEEE | en_US |
| dc.title | A flexible pressure monitoring system for pressure ulcer prevention | en_US |
| dc.type | Article | en_US |
| dc.identifier.citation | Yip, M. et al. “A flexible pressure monitoring system for pressure ulcer prevention.” Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE. 2009. 1212-1215. | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science | en_US |
| dc.contributor.approver | Winokur, Eric S. | |
| dc.contributor.mitauthor | Yip, Marcus | |
| dc.contributor.mitauthor | He, David Da | |
| dc.contributor.mitauthor | Winokur, Eric S. | |
| dc.contributor.mitauthor | Balderrama, Amanda Gaudreau | |
| dc.relation.journal | Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2009 | en_US |
| dc.eprint.version | Final published version | en_US |
| dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
| eprint.status | http://purl.org/eprint/status/PeerReviewed | en_US |
| dspace.orderedauthors | Yip, M.; He, D.D.; Winokur, E.; Balderrama, A.G.; Sheridan, R.; Hongshen Ma, R. | en |
| mit.license | PUBLISHER_POLICY | en_US |
| mit.metadata.status | Complete | |