Show simple item record

dc.contributor.authorStepp, Cara E.
dc.contributor.authorHeaton, James T.
dc.contributor.authorRolland, Rebecca G.
dc.contributor.authorHillman, Robert E.
dc.date.accessioned2011-03-11T15:25:40Z
dc.date.available2011-03-11T15:25:40Z
dc.date.issued2009-04
dc.date.submitted2008-11
dc.identifier.issn1534-4320
dc.identifier.otherINSPEC Accession Number: 10560665
dc.identifier.urihttp://hdl.handle.net/1721.1/61666
dc.description.abstractThe electrolarynx (EL) is a common rehabilitative speech aid for individuals who have undergone total laryngectomy, but they typically lack pitch control and require the exclusive use of one hand. The viability of using neck and face surface electromyography (sEMG) to control the onset, offset, and pitch of an EMG-controlled EL (EMG-EL) was studied. Eight individuals who had undergone total laryngectomy produced serial and running speech using a typical handheld EL and the EMG-EL while attending to real-time visual sEMG biofeedback. Running speech tokens produced with the EMG-EL were examined for naturalness by 10 listeners relative to those produced with a typical EL using a visual analog scale. Serial speech performance was assessed as the percentage of words that were fully voiced and pauses that were successfully produced. Results of the visual analog scale assessment indicated that individuals were able to use the EMG-EL without training to produce running speech perceived as natural as that produced with a typical handheld EL. All participants were able to produce running and serial speech with the EMG-EL controlled by sEMG from multiple recording locations, with the superior ventral neck or submental surface locations providing at least one of the two best control locations.en_US
dc.description.sponsorshipNational Institute on Deafness and Other Communication Disorders (U.S.) (Grant R01-DC006449)en_US
dc.language.isoen_US
dc.publisherInstitute of Electrical and Electronics Engineersen_US
dc.relation.isversionofhttp://dx.doi.org/10.1109/TNSRE.2009.2017805en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceIEEEen_US
dc.titleNeck and face surface electromyography for prosthetic voice control after total laryngectomyen_US
dc.typeArticleen_US
dc.identifier.citationStepp, C.E. et al. “Neck and Face Surface Electromyography for Prosthetic Voice Control After Total Laryngectomy.” Neural Systems and Rehabilitation Engineering, IEEE Transactions on 17.2 (2009): 146-155. © 2009 IEEE.en_US
dc.contributor.departmentHarvard University--MIT Division of Health Sciences and Technologyen_US
dc.contributor.approverHillman, Robert E.
dc.contributor.mitauthorHillman, Robert E.
dc.contributor.mitauthorStepp, Cara E.
dc.relation.journalIEEE Transactions on Neural Systems and Rehabilitation Engineeringen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
dspace.orderedauthorsStepp, C.E.; Heaton, J.T.; Rolland, R.G.; Hillman, R.E.en
mit.licensePUBLISHER_POLICYen_US