Show simple item record

dc.contributor.authorArai, Tatsuya
dc.contributor.authorLee, Kichang
dc.contributor.authorCohen, Richard J.
dc.date.accessioned2011-07-29T19:28:34Z
dc.date.available2011-07-29T19:28:34Z
dc.date.issued2010-08
dc.date.submitted2010-04
dc.identifier.isbn978-1-4244-4123-5
dc.identifier.issn1557-170X
dc.identifier.otherINSPEC Accession Number: 11660115
dc.identifier.urihttp://hdl.handle.net/1721.1/64992
dc.description.abstractCardiac output (CO) and stroke volume (SV) are the key hemodynamic parameters to be monitored and assessed in ambulatory and critically ill patients. The purpose of this study was to introduce and validate a new algorithm to continuously estimate, within a proportionality constant, CO and SV by means of mathematical analysis of peripheral arterial blood pressure (ABP) waveforms. The algorithm combines three variants of the Windkessel model. Input parameters to the algorithm are the end-diastolic pressure, mean arterial pressures, inter-beat interval, and the time interval from end-diastolic to peak systolic pressure. The SV estimates from the three variants of the Windkessel model were weighted and integrated to provide beat-to-beat SV estimation. In order to validate the new algorithm, the estimated CO and SV were compared to those obtained through surgically implanted Transonic™ aortic flow probes placed around the aortic roots of six Yorkshire swine. Overall, estimation errors in CO and SV derived from radial ABP were 10.1% and 14.5% respectively, and 12.7% and 16.5% from femoral ABP. The new algorithm demonstrated statistically significant improvement in SV estimation compared with previous methods.en_US
dc.language.isoen_US
dc.publisherInstitute of Electrical and Electronics Engineersen_US
dc.relation.isversionofhttp://dx.doi.org/10.1109/iembs.2010.5627225en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceIEEEen_US
dc.titleCardiac output and stroke volume estimation using a hybrid of three modelsen_US
dc.typeArticleen_US
dc.identifier.citationArai, T., Kichang Lee, and R.J. Cohen. “Cardiac Output and Stroke Volume Estimation Using a Hybrid of Three Windkessel Models.” Engineering in Medicine and Biology Society (EMBC), 2010 32nd Annual International Conference of the IEEE. Buenos Aires, Argentina, August 31 - September 4, 2010. 4971-4974. © 2011 IEEE.en_US
dc.contributor.departmentHarvard University--MIT Division of Health Sciences and Technologyen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Aeronautics and Astronauticsen_US
dc.contributor.approverCohen, Richard J.
dc.contributor.mitauthorArai, Tatsuya
dc.contributor.mitauthorLee, Kichang
dc.contributor.mitauthorCohen, Richard J.
dc.relation.journalProceedings of the 32nd Annual International Conference of the IEEE, Engineering in Medicine and Biology Society (EMBC 2010)en_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
dspace.orderedauthorsArai, Tatsuya; Kichang Lee, Tatsuya; Cohen, Richard Jen
dc.identifier.orcidhttps://orcid.org/0000-0002-4058-3832
dc.identifier.orcidhttps://orcid.org/0000-0002-5573-0137
mit.licensePUBLISHER_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record