Reply to “Comment on ‘Determination of the bulk melting temperature of nickel using Monte Carlo simulations: Inaccuracy of extrapolation from cluster melting temperatures' ”
Author(s)
Los, J. H.; Pellenq, Roland J. -M.
DownloadLos-2011-Reply to “Comment on ‘Determination of the bulk.pdf (118.0Kb)
PUBLISHER_POLICY
Publisher Policy
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Terms of use
Metadata
Show full item recordAbstract
The thermodynamic integration (TI) method for determining the melting temperature has to be performed with great care to ensure accuracy. Since the slopes of the Gibbs free energy curves as a function of temperature (or pressure) are usually rather close, small shifts in the free energy curves can lead to a large change in the calculated melting temperature. In this Reply to a Comment by Harvey and Gheribi [ Phys. Rev. B 84 096102 (2011)] on our paper [ Phys. Rev. B 81 064112 (2010)], we show that the error in the calculated melting temperature of nickel induced by some technical imperfections in our application of the TI method, as noticed and described in the Comment, is small compared to the error bar given in our paper. We also clarify supposed doubts about the accuracy of the TI method based on Johnson's free energy expression and parametrization [ Johnson et al. Mol. Phys. 78 591 (1993)] of the Lennard-Jones fluid.
Date issued
2011-09Department
Massachusetts Institute of Technology. Department of Civil and Environmental EngineeringJournal
Physical Review B
Publisher
American Physical Society
Citation
Los, J., and R. J. Pellenq. “Reply to ‘Comment on “Determination of the Bulk Melting Temperature of Nickel Using Monte Carlo Simulations: Inaccuracy of Extrapolation from Cluster Melting Temperatures” ’.” Physical Review B 84.9 (2011): [3 pages]. ©2011 American Physical Society.
Version: Final published version
ISSN
1098-0121
1550-235X