dc.description.abstractIn order to study the flashover mechanism of polluted insulators under AC voltage, a new arc propagation criterion which is based on an arc root voltage gradient is proposed. This criterion can explain the variation of the arc root voltage gradient in the arc propagation process. Based on this criterion, a new distributed parameter electrical circuit flashover model of polluted insulators is presented. The arc channel is considered as an equivalent distributed parameter circuit model instead of using the arc voltage-gradient equation. The parameters of the arc model are obtained from the electromagnetic field distribution of the arc and the gas discharge theories. The arc root is considered as parallel paths including the polluted layer. The variation of the voltage on the arc root is related to the capability of arc propagation. This model takes the microscopic mechanism of arc root ionization into consideration, which can improve the accuracy of the flashover model. The results obtained from the presented model are in good agreement with other mathematical and experimental results.en_US
dc.description.sponsorshipNational Basic Research Program of China (973 Program) (2009CB724507)en_US
dc.description.sponsorshipNational 111 Project of China (B08036)en_US
dc.language.isoen_US
dc.publisherMDPI AGen_US
dc.relation.isversionofhttp://dx.doi.org/10.3390/en5030752en_US
dc.rightsCreative Commons Attribution 3.0en_US
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/en_US
dc.sourceMDPIen_US
dc.titleElectrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterionen_US
dc.typeArticleen_US
dc.identifier.citationYang, Qing et al. “Electrical Circuit Flashover Model of Polluted Insulators Under AC Voltage Based on the Arc Root Voltage Gradient Criterion.” Energies 5.3 (2012): 752–769. Web. 3 May 2012.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Scienceen_US
dc.contributor.departmentMassachusetts Institute of Technology. High Voltage Research Laboratoryen_US
dc.contributor.departmentMassachusetts Institute of Technology. Laboratory for Electromagnetic and Electronic Systemsen_US
dc.contributor.departmentMassachusetts Institute of Technology. Research Laboratory of Electronicsen_US
dc.contributor.approverZahn, Markus
dc.contributor.mitauthorZahn, Markus
dc.relation.journalEnergiesen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsYang, Qing; Wang, Rui; Sima, Wenxia; Jiang, Chilong; Lan, Xing; Zahn, Markusen
dc.identifier.orcidhttps://orcid.org/0000-0003-2228-2347
mit.licensePUBLISHER_CCen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record