Retinal nerve fibre layer and visual function loss in glaucoma: the tipping point
Author(s)
Wollstein, Gadi; Kagemann, Larry; Bilonick, Richard A.; Ishikawa, Hiroshi; Folio, Lindsey S.; Gabriele, Michelle L.; Ungar, Allison K.; Duker, Jay S.; Fujimoto, James G.; Schuman, Joel S.; ... Show more Show less
DownloadWollstein-2012-Retinal nerve fibre layer and visual function loss in.pdf (364.4Kb)
PUBLISHER_POLICY
Publisher Policy
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Terms of use
Metadata
Show full item recordAbstract
Aims To determine the retinal nerve fibre layer (RNFL) thickness at which visual field (VF) damage becomes detectable and associated with structural loss.
Methods In a prospective cross-sectional study, 72 healthy and 40 glaucoma subjects (one eye per subject) recruited from an academic institution had VF examinations and spectral domain optical coherence tomography (SD-OCT) optic disc cube scans (Humphrey field analyser and Cirrus HD-OCT, respectively). Comparison of global mean and sectoral RNFL thicknesses with VF threshold values showed a plateau of threshold values at high RNFL thicknesses and a sharp decrease at lower RNFL thicknesses. A ‘broken stick’ statistical model was fitted to global and sectoral data to estimate the RNFL thickness ‘tipping point’ where the VF threshold values become associated with the structural measurements. The slope for the association between structure and function was computed for data above and below the tipping point.
Results The mean RNFL thickness threshold for VF loss was 75.3 μm (95% CI: 68.9 to 81.8), reflecting a 17.3% RNFL thickness loss from age-matched normative value. Above the tipping point, the slope for RNFL thickness and threshold value was 0.03 dB/μm (CI: −0.02 to 0.08) and below the tipping point, it was 0.28 dB/μm (CI: 0.18 to 0.38); the difference between the slopes was statistically significant (p<0.001). A similar pattern was observed for quadrant and clock-hour analysis.
Conclusions Substantial structural loss (∼17%) appears to be necessary for functional loss to be detectable using the current testing methods
Date issued
2011-04Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Research Laboratory of ElectronicsJournal
British Journal of Ophthalmology
Publisher
BMJ Publishing Group
Citation
Wollstein, G. et al. “Retinal Nerve Fibre Layer and Visual Function Loss in Glaucoma: The Tipping Point.” British Journal of Ophthalmology 96.1 (2011): 47–52. Web. © 2011 by the BMJ Publishing Group Ltd.
Version: Final published version
ISSN
0007-1161
1468-2079