Show simple item record

dc.contributor.authorFletcher, Richard Ribon
dc.contributor.authorKulkarni, Sarang
dc.date.accessioned2012-06-20T18:33:21Z
dc.date.available2012-06-20T18:33:21Z
dc.date.issued2010-01
dc.identifier.isbn978-1-4244-4726-8
dc.identifier.isbn978-1-4244-4725-1
dc.identifier.otherINSPEC Accession Number: 11190845
dc.identifier.urihttp://hdl.handle.net/1721.1/71181
dc.description.abstractA 2.45 GHz wearable Doppler radar unit with radio data link is presented for use in portable patient monitoring and emergency response. Unlike portable Electrocardiograms (ECG) or Photoplethysmography (PPG), the near-field Doppler unit enables monitoring of the person's heart rate without the need for electrical contact or optical access to the patient's skin. The Doppler unit is designed to be embedded in a clothing garment such as a shirt or vest, or used by medical emergency personal in an instrumented blanket or medical stretcher. Since the Doppler unit is placed directly on or behind the patient's torso, the extraneous signals due to relative motion artifacts is greatly reduced. Low-cost design is achieved by employing PWB microstrip elements for the integrated patch antenna, microwave oscillator, and tuning elements. Also, since the distance between the Doppler unit and the patient is fixed, it was possible to tune the detection phase to enable the use of a single mixer diode and eliminate the need for quadrature detection. Measured heart data from this technique shows clear waveform substructure similar to PQRST complex features found in captured ECG data.en_US
dc.language.isoen_US
dc.publisherInstitute of Electrical and Electronics Engineersen_US
dc.relation.isversionofhttp://dx.doi.org/10.1109/RWS.2010.5434220en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceIEEEen_US
dc.titleWearable Doppler radar with integrated antenna for patient vital sign monitoringen_US
dc.typeArticleen_US
dc.identifier.citationFletcher, Richard Ribon, and Sarang Kulkarni. “Wearable Doppler Radar with Integrated Antenna for Patient Vital Sign Monitoring.” IEEE, 2010. 276–279. Web.© 2010 IEEE.en_US
dc.contributor.departmentMIT-SUTD Collaboration Officeen_US
dc.contributor.approverFletcher, Richard R.
dc.contributor.mitauthorFletcher, Richard Ribon
dc.contributor.mitauthorKulkarni, Sarang
dc.relation.journalProceedings of the 2010 IEEE Radio and Wireless Symposium (RWS)en_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/ConferencePaperen_US
dspace.orderedauthorsFletcher, Richard Ribon; Kulkarni, Sarangen
mit.licensePUBLISHER_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record