First results from the MIT optical rapid imaging system (MORIS) on the IRTF: A stellar occultation by Pluto and a transit by exoplanet XO-2b
Author(s)
Gulbis, Amanda A. S.; Bus, S. J.; Rayner, J. T.; Stahlberger, W. E.; Rojas, Folkers E.; Adams, Elisabeth Rose; Person, Michael J.; Chung, R.; Tokunaga, A. T.; Zuluaga, Carlos Andres; Elliot, James L.; ... Show more Show less
DownloadElliot_First results.pdf (1.818Mb)
OPEN_ACCESS_POLICY
Open Access Policy
Creative Commons Attribution-Noncommercial-Share Alike
Terms of use
Metadata
Show full item recordAbstract
We present a high-speed, visible-wavelength imaging instrument: MORIS (the MIT Optical Rapid Imaging System). MORIS is mounted on the 3 m Infrared Telescope Facility (IRTF) on Mauna Kea, Hawaii. Its primary component is an Andor iXon camera, a nearly 60" square field of view with high quantum efficiency, low read noise, low dark current, and full-frame readout rates ranging from as slow as desired to a maximum of between 3.5 Hz and 35 Hz (depending on the mode; read noise of 6 pixel and 49 pixel with electron-multiplying gain = 1 , respectively). User-selectable binning and subframing can increase the cadence to a few hundred hertz. An electron-multiplying mode can be employed for photon counting, effectively reducing the read noise to subelectron levels at the expense of dynamic range. Data cubes, or individual frames, can be triggered to several-nanosecond accuracy using the Global Positioning System. MORIS is mounted on the side-facing exit window of SpeX, allowing simultaneous near-infrared and visible observations. Here, we describe the components, setup, and measured characteristics of MORIS. We also report results from the first science observations: the 2008 June 24 stellar occultation by Pluto and an extrasolar planetary transit by XO-2b. The Pluto occultation of a 15.8 magnitude star has a signal-to-noise ratio of 35 per atmospheric scale height and a midtime error of 0.32 s. The XO-2b transit reaches photometric precision of 0.5 mmag in 2 minutes and has a midtime timing precision of 23 s.
Date issued
2011-04Department
Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences; Massachusetts Institute of Technology. Department of Mechanical EngineeringJournal
Publications of the Astronomical Society of the Pacific
Publisher
University of Chicago Press, The
Citation
Gulbis, A. A. S. et al. “First Results from the MIT Optical Rapid Imaging System (MORIS) on the IRTF: A Stellar Occultation by Pluto and a Transit by Exoplanet XO-2b.” Publications of the Astronomical Society of the Pacific 123.902 (2011): 461–469.
Version: Author's final manuscript
ISSN
0004-6280
1538-3873