MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Closed loop performance of polypyrrole linear contractile actuators

Author(s)
Paster, Eli Travis; Ruddy, Bryan P.; Pillai, Priam V.; Hunter, Ian
Thumbnail
DownloadHunter_Closed loop.pdf (1.909Mb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Conducting polymer actuators such as polypyrrole can generate stresses over 10 times larger than skeletal muscle and have typical repeatable strains between 1% and 12%, making them potential candidates for lightweight, low-cost, robotic applications. Polypyrrole linear actuators under closed loop control have not been previously reported. Here we report the open and closed loop performance of polypyrrole linear contractile actuators evaluated at pre-loaded stresses of 1 MPa to 3 MPa. A standard PI control scheme driving a potentiostat was implemented in conjunction with positioning feedback from a DC/DC linear variable differential transformer (LVDT). A dynamic positioning range of 3400 is reported, with a positioning resolution of 125 nm (0.001% strain) and a maximum repeatable displacement of 427 microns (3.6% strain). The open loop frequency response of actuator strain shows characteristics of a first-order low pass filter with a log gain versus log frequency slope near -1 for frequencies tested between 0.05 Hz to 2 Hz. The closed loop frequency response of actuator strain when tracking a sinusoidal set-point signal of 0.5% strain shows characteristics of a first order system with one zero, with a corner frequency near 0.08 Hz and an operating bandwidth up to 1 Hz. Step responses at various controller output maximum voltages show a reduction in contractile response times by a factor of four, where higher voltages yield faster contractile responses.
Date issued
2010-05
URI
http://hdl.handle.net/1721.1/78639
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
IEEE International Conference on Robotics and Automation (ICRA), 2010
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Paster, Eli, Bryan P Ruddy, Priam V Pillai, and Ian W Hunter. Closed Loop Performance of Polypyrrole Linear Contractile Actuators. In Pp. 506–511. IEEE, 2010. © Copyright 2010 IEEE
Version: Final published version
ISBN
978-1-4244-5040-4
978-1-4244-5038-1
ISSN
1050-4729

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.