Show simple item record

dc.contributor.authorSrinivasan, Siddarth
dc.contributor.authorMcKinley, Gareth H.
dc.contributor.authorCohen, Robert E.
dc.date.accessioned2013-06-12T20:53:36Z
dc.date.available2013-06-12T20:53:36Z
dc.date.issued2011-11
dc.date.submitted2011-09
dc.identifier.issn0743-7463
dc.identifier.issn1520-5827
dc.identifier.urihttp://hdl.handle.net/1721.1/79097
dc.description.abstractGravity-induced sagging can amplify variations in goniometric measurements of the contact angles of sessile drops on super-liquid-repellent surfaces. The very large value of the effective contact angle leads to increased optical noise in the drop profile near the solid–liquid free surface and the progressive failure of simple geometric approximations. We demonstrate a systematic approach to determining the effective contact angle of drops on super-repellent surfaces. We use a perturbation solution of the Bashforth–Adams equation to estimate the contact angles of sessile drops of water, ethylene glycol, and diiodomethane on an omniphobic surface using direct measurements of the maximum drop width and height. The results and analysis can be represented in terms of a dimensionless Bond number that depends on the maximum drop width and the capillary length of the liquid to quantify the extent of gravity-induced sagging. Finally, we illustrate the inherent sensitivity of goniometric contact angle measurement techniques to drop dimensions as the apparent contact angle approaches 180°.en_US
dc.description.sponsorshipUnited States. Army Research Office (Contract W911NF-07-D-0004)en_US
dc.language.isoen_US
dc.publisherAmerican Chemical Society (ACS)en_US
dc.relation.isversionofhttp://dx.doi.org/10.1021/la2031208en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceMIT web domainen_US
dc.titleAssessing the Accuracy of Contact Angle Measurements for Sessile Drops on Liquid-Repellent Surfacesen_US
dc.typeArticleen_US
dc.identifier.citationSrinivasan, Siddarth, Gareth H. McKinley, and Robert E. Cohen. “Assessing the Accuracy of Contact Angle Measurements for Sessile Drops on Liquid-Repellent Surfaces.” Langmuir 27.22 (2011): 13582–13589.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Chemical Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. School of Engineeringen_US
dc.contributor.mitauthorSrinivasan, Siddarthen_US
dc.contributor.mitauthorMcKinley, Gareth H.en_US
dc.contributor.mitauthorCohen, Robert E.en_US
dc.relation.journalLangmuiren_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsSrinivasan, Siddarth; McKinley, Gareth H.; Cohen, Robert E.en_US
dc.identifier.orcidhttps://orcid.org/0000-0003-4591-6090
dc.identifier.orcidhttps://orcid.org/0000-0001-8323-2779
dc.identifier.orcidhttps://orcid.org/0000-0003-1085-7692
mit.licensePUBLISHER_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record