Show simple item record

dc.contributor.authorChen, Tianyuan
dc.contributor.authorZhang, Ning
dc.contributor.authorHuo, Tiancheng
dc.contributor.authorWang, Chengming
dc.contributor.authorZheng, Jing-gao
dc.contributor.authorZhou, Tieying
dc.contributor.authorXue, Ping
dc.date.accessioned2013-12-23T17:50:51Z
dc.date.available2013-12-23T17:50:51Z
dc.date.issued2013-08
dc.date.submitted2013-07
dc.identifier.issn1083-3668
dc.identifier.issn1560-2281
dc.identifier.urihttp://hdl.handle.net/1721.1/83223
dc.description.abstractWe present an endoscopic probe for optical coherence tomography (OCT) equipped with a miniaturized hollow ultrasonic motor that rotates the objective lens and provides an internal channel for the fiber to pass through, enabling 360 deg unobstructed circumferential scanning. This probe has an outer diameter of 1.5 mm, which is ultra-small for motorized probes with an unobstructed view in distal scanning endoscopic OCT. Instead of a mirror or prism, a customized aspheric right-angle lens is utilized, leading to an enlargement of the numerical aperture and thus high transverse resolution. Spectral-domain OCT imaging of bio-tissue and a phantom are demonstrated with resolution of 7.5  μm (axial) × 6.6  μm (lateral) and sensitivity of 96 dB.en_US
dc.language.isoen_US
dc.publisherSPIEen_US
dc.relation.isversionofhttp://dx.doi.org/10.1117/1.jbo.18.8.086011en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSPIEen_US
dc.titleTiny endoscopic optical coherence tomography probe driven by a miniaturized hollow ultrasonic motoren_US
dc.typeArticleen_US
dc.identifier.citationChen, Tianyuan, Ning Zhang, Tiancheng Huo, Chengming Wang, Jing-gao Zheng, Tieying Zhou, and Ping Xue. “Tiny endoscopic optical coherence tomography probe driven by a miniaturized hollow ultrasonic motor.” Journal of Biomedical Optics 18, no. 8 (August 1, 2013): 086011.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Scienceen_US
dc.contributor.departmentMassachusetts Institute of Technology. Research Laboratory of Electronicsen_US
dc.contributor.mitauthorZhang, Ningen_US
dc.relation.journalJournal of Biomedical Opticsen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsChen, Tianyuan; Zhang, Ning; Huo, Tiancheng; Wang, Chengming; Zheng, Jing-gao; Zhou, Tieying; Xue, Pingen_US
mit.licensePUBLISHER_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)