QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling
Author(s)
Bolar, Divya Sanam; Rosen, Bruce R.; Sorenson, A. G.; Adalsteinsson, Elfar
DownloadAdalsteinsson_Quantitative imaging.pdf (1.551Mb)
OPEN_ACCESS_POLICY
Open Access Policy
Creative Commons Attribution-Noncommercial-Share Alike
Terms of use
Metadata
Show full item recordAbstract
While oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) are fundamental parameters of brain health and function, a robust MRI-based mapping of OEF and CMRO2 amenable to functional MRI (fMRI) has not been established. To address this issue, a novel method called QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption, or QUIXOTIC, is introduced. The key innovation in QUIXOTIC is the use of velocity-selective spin labeling to isolate MR signal exclusively from postcapillary venular blood on a voxel-by-voxel basis. Measuring the T2 of this venular-targeted blood allows calibration to venular oxygen saturation (Yv) via theoretical and experimental T2 versus blood oxygen saturation relationships. Yv is converted to OEF, and baseline CMRO2 is subsequently estimated from OEF and additional cerebral blood flow and hematocrit measurements. Theory behind the QUIXOTIC technique is presented, and implications of cutoff velocity (VCUTOFF) and outflow time parameters are discussed. Cortical gray matter values obtained with QUIXOTIC in 10 healthy volunteers are Yv = 0.73 ± 0.02, OEF = 0.26 ± 0.02, and CMRO2 = 125 ± 15 μmol/100 g min. Results are compared to global measures obtained with the T2 relaxation under spin tagging (TRUST) technique. The preliminary data presented suggest that QUIXOTIC will be useful for mapping Yv, OEF, and CMRO2, in both clinical and functional MRI settings.
Description
available in PMC 2012 December 1
Date issued
2011-12Department
Harvard University--MIT Division of Health Sciences and Technology; Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Research Laboratory of ElectronicsJournal
Magnetic Resonance in Medicine
Publisher
John Wiley & Sons, Inc
Citation
Bolar, D. S., B. R. Rosen, A. G. Sorensen, and E. Adalsteinsson. “QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption (QUIXOTIC) Using Venular-Targeted Velocity-Selective Spin Labeling.” Magnetic Resonance in Medicine 66, no. 6 (December 2011): 1550–1562.
Version: Author's final manuscript
ISSN
07403194