MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
  • DSpace@MIT Home
  • MIT Open Access Articles
  • MIT Open Access Articles
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular-targeted velocity-selective spin labeling

Author(s)
Bolar, Divya Sanam; Rosen, Bruce R.; Sorenson, A. G.; Adalsteinsson, Elfar
Thumbnail
DownloadAdalsteinsson_Quantitative imaging.pdf (1.551Mb)
OPEN_ACCESS_POLICY

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
While oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) are fundamental parameters of brain health and function, a robust MRI-based mapping of OEF and CMRO2 amenable to functional MRI (fMRI) has not been established. To address this issue, a novel method called QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption, or QUIXOTIC, is introduced. The key innovation in QUIXOTIC is the use of velocity-selective spin labeling to isolate MR signal exclusively from postcapillary venular blood on a voxel-by-voxel basis. Measuring the T2 of this venular-targeted blood allows calibration to venular oxygen saturation (Yv) via theoretical and experimental T2 versus blood oxygen saturation relationships. Yv is converted to OEF, and baseline CMRO2 is subsequently estimated from OEF and additional cerebral blood flow and hematocrit measurements. Theory behind the QUIXOTIC technique is presented, and implications of cutoff velocity (VCUTOFF) and outflow time parameters are discussed. Cortical gray matter values obtained with QUIXOTIC in 10 healthy volunteers are Yv = 0.73 ± 0.02, OEF = 0.26 ± 0.02, and CMRO2 = 125 ± 15 μmol/100 g min. Results are compared to global measures obtained with the T2 relaxation under spin tagging (TRUST) technique. The preliminary data presented suggest that QUIXOTIC will be useful for mapping Yv, OEF, and CMRO2, in both clinical and functional MRI settings.
Description
available in PMC 2012 December 1
Date issued
2011-12
URI
http://hdl.handle.net/1721.1/85922
Department
Harvard University--MIT Division of Health Sciences and Technology; Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Research Laboratory of Electronics
Journal
Magnetic Resonance in Medicine
Publisher
John Wiley & Sons, Inc
Citation
Bolar, D. S., B. R. Rosen, A. G. Sorensen, and E. Adalsteinsson. “QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption (QUIXOTIC) Using Venular-Targeted Velocity-Selective Spin Labeling.” Magnetic Resonance in Medicine 66, no. 6 (December 2011): 1550–1562.
Version: Author's final manuscript
ISSN
07403194

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.