Phase-based measures of cross-frequency coupling in brain electrical dynamics under general anesthesia

Author(s)
Wong, Kin Foon; Brown, Emery N.; Purdon, Patrick Lee; Mukamel, Eran A.; Prerau, Michael J.
Thumbnail
DownloadBrown_Phase-based measures.pdf (1.297Mb)
OPEN_ACCESS_POLICY

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
The state of general anesthesia (GA) is associated with an increase in spectral power in scalp electroencephalogram (EEG) at frequencies below 40 Hz, including spectral peaks in the slow oscillation (SO, 0.1-1 Hz) and α (8-14 Hz) bands. Because conventional power spectral analyses are insensitive to possible cross-frequency coupling, the relationships among the oscillations at different frequencies remain largely unexplored. Quantifying such coupling is essential for improving clinical monitoring of anesthesia and understanding the neuroscience of this brain state. We tested the usefulness of two measures of cross-frequency coupling: the bispectrum-derived SynchFastSlow, which is sensitive to phase-phase coupling in different frequency bands, and modulogram analysis of coupling between SO phase and α rhythm amplitude. SynchFastSlow, a metric that is used in clinical depth-of-anesthesia monitors, showed a robust correlation with the loss of consciousness at the induction of propofol GA, but this could be largely explained by power spectral changes without considering cross-frequency coupling. Modulogram analysis revealed two distinct modes of cross-frequency coupling under GA. The waking and two distinct states under GA could be discriminated by projecting in a two-dimensional phase space defined by the SynchFastSlow and the preferred SO phase of α activity. Our results show that a stereotyped pattern of phase-amplitude coupling accompanies multiple stages of anesthetic-induced unconsciousness. These findings suggest that modulogram analysis can improve EEG based monitoring of brain state under GA.
Date issued
2011-08
URI
http://hdl.handle.net/1721.1/86321
Department
Harvard University--MIT Division of Health Sciences and Technology; Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
Journal
Proceedings of the 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Mukamel, E. A., K. F. Wong, M. J. Prerau, E. N. Brown, and P. L. Purdon. “Phase-Based Measures of Cross-Frequency Coupling in Brain Electrical Dynamics Under General Anesthesia.” 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (n.d.).
Version: Author's final manuscript
ISBN
978-1-4577-1589-1
978-1-4244-4121-1
978-1-4244-4122-8

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.