EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE
Author(s)
Alwassia, Ahmad A.; Adhi, Mehreen; Zhang, Jason Y.; Regatieri, Caio V.; Al-Quthami, Adeeb; Salem, Deeb; Fujimoto, James G.; Duker, Jay S.; ... Show more Show less
DownloadFujimoto_Excercise-induced acute.pdf (533.1Kb)
OPEN_ACCESS_POLICY
Open Access Policy
Creative Commons Attribution-Noncommercial-Share Alike
Terms of use
Metadata
Show full item recordAbstract
Purpose: To measure choroidal thickness in patients manifesting an acute change in systemic arterial blood pressure using a portable spectral-domain optical coherence tomography device (iVue).
Methods: Fifteen patients (15 eyes) undergoing cardiac exercise stress testing were scanned using a portable spectral-domain optical coherence tomography system (iVue). Two scan protocols were used: cross line scan for measuring choroidal thickness and the retina map scan to measure retinal thickness. Each patient was scanned before and within 3 minutes after the stress test. Blood pressure was measured at the same time as the acquisition of the scans. Choroidal thickness was measured from the posterior edge of the retinal pigment epithelium to the choroid–sclera junction at 500-μm intervals up to 1,000 μm temporal and nasal to the fovea. Retinal thickness was measured by an automated software. All choroidal thickness measurements were performed by two independent observers.
Results: Fifteen patients (15 eyes) with a mean age of 60.6 (±10.4 years) were scanned. There was a significant increase in systolic but not diastolic pressure after stress testing (P < 0.05). The mean choroidal thickness measurements showed no significant difference before and after exercise stress testing (P > 0.05). In addition, there was no significant difference in retinal thickness before and after stress testing measurements (P > 0.05).
Conclusion: There was no change in choroidal thickness or retinal thickness, despite an acute change in the systemic systolic blood pressure induced by exercise.
Date issued
2013-01Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Research Laboratory of ElectronicsJournal
Retina
Publisher
Ovid Technologies (Wolters Kluwer) - Lippincott Williams & Wilkins
Citation
Alwassia, Ahmad A., Mehreen Adhi, Jason Y. Zhang, Caio V. Regatieri, Adeeb Al-Quthami, Deeb Salem, James G. Fujimoto, and Jay S. Duker. “EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE.” Retina 33, no. 1 (January 2013): 160–165.
Version: Author's final manuscript
ISSN
0275-004X