Spectral oximetry assessed with high-speed ultra-high-resolution optical coherence tomography
Author(s)
Kagemann, Larry; Wollstein, Gadi; Wojtkowski, Maciej; Ishikawa, Hiroshi; Townsend, Kelly A.; Gabriele, Michelle L.; Srinivasan, Vivek J.; Fujimoto, James G.; Schuman, Joel S.; ... Show more Show less
DownloadKagemann-2007-Spectral oximetry as.pdf (934.0Kb)
PUBLISHER_POLICY
Publisher Policy
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Terms of use
Metadata
Show full item recordAbstract
We use Fourier domain optical coherence tomography (OCT) data to assess retinal blood oxygen saturation. Three-dimensional disk-centered retinal tissue volumes were assessed in 17 normal healthy subjects. After removing DC and low-frequency a-scan components, an OCT fundus image was created by integrating total reflectance into a single reflectance value. Thirty fringe patterns were sampled; 10 each from the edge of an artery, adjacent tissue, and the edge of a vein, respectively. A-scans were recalculated, zeroing the DC term in the power spectrum, and used for analysis. Optical density ratios (ODRs) were calculated as ODR[subscript Art] = ln(Tissue[subscript 855]/Art[subscript 855])/ln(Tissue[subscript 805]/Art[subscript 805) and ODR[subscript Vein] = ln(Tissue[subscript 855]/Vein[subscript 855])/ln(Tissue[subscript 805]/Vein[subscript 805]) with Tissue, Art, and Vein representing total a-scan reflectance at the 805- or 855-nm centered bandwidth. Arterial and venous ODRs were compared by the Wilcoxon signed rank test. Arterial ODRs were significantly greater than venous ODRs (1.007 ± 2.611 and −1.434 ± 4.310, respectively; p = 0.0217) (mean±standard deviation). A difference between arterial and venous blood saturation was detected. This suggests that retinal oximetry may possibly be added as a metabolic measurement in structural imaging devices.
Date issued
2007-08Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science; Massachusetts Institute of Technology. Research Laboratory of ElectronicsJournal
Journal of Biomedical Optics
Publisher
SPIE
Citation
Kagemann, Larry, Gadi Wollstein, Maciej Wojtkowski, Hiroshi Ishikawa, Kelly A. Townsend, Michelle L. Gabriele, Vivek J. Srinivasan, James G. Fujimoto, and Joel S. Schuman. “Spectral Oximetry Assessed with High-Speed Ultra-High-Resolution Optical Coherence Tomography.” Journal of Biomedical Optics 12, no. 4 (2007): 041212. © 2007 Society of Photo-Optical Instrumentation Engineers
Version: Final published version
ISSN
10833668
1560-2281