Show simple item record

dc.contributor.authorBriese, T
dc.contributor.authorBugel, Leonard G.
dc.contributor.authorConrad, Janet
dc.contributor.authorFournier, M.
dc.contributor.authorIgnarra, Christina
dc.contributor.authorJones, Benjamin James Poyner
dc.contributor.authorKatori, Teppei
dc.contributor.authorNavarrete-Perez, R.
dc.contributor.authorNienaber, P.
dc.contributor.authorMcDonald, T.
dc.contributor.authorMusolf, B.
dc.contributor.authorPrakash, A.
dc.contributor.authorShockley, E.
dc.contributor.authorSmidt, T.
dc.contributor.authorSwanson, K.
dc.contributor.authorToups, Matthew
dc.date.accessioned2014-07-15T19:07:27Z
dc.date.available2014-07-15T19:07:27Z
dc.date.issued2013-07
dc.date.submitted2013-06
dc.identifier.issn1748-0221
dc.identifier.urihttp://hdl.handle.net/1721.1/88415
dc.description.abstractThe MicroBooNE detector, to be located on axis in the Booster Neutrino Beamline (BNB) at the Fermi National Accelerator Laboratory (Fermilab), consists of two main components: a large liquid argon time projection chamber (LArTPC), and a light collection system. Thirty-two 8-inch diameter Hamamatsu R5912-02mod cryogenic photomultiplier tubes (PMTs) will detect the scintillation light generated in the liquid argon (LAr). This article first describes the MicroBooNE PMT performance test procedures, including how the light collection system functions in the detector, and the design of the PMT base. The design of the cryogenic test stand is then discussed, and finally the results of the cryogenic tests are reported.en_US
dc.description.sponsorshipNational Science Foundation (U.S.) (NSF-PHY-0847843)en_US
dc.description.sponsorshipNational Science Foundation (U.S.) (NSF PHY-1000214)en_US
dc.language.isoen_US
dc.publisherInstitute of Physics Publishingen_US
dc.relation.isversionofhttp://dx.doi.org/10.1088/1748-0221/8/07/t07005en_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alikeen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/en_US
dc.sourcearXiven_US
dc.titleTesting of cryogenic photomultiplier tubes for the MicroBooNE experimenten_US
dc.typeArticleen_US
dc.identifier.citationBriese, T, L Bugel, J M Conrad, M Fournier, C Ignarra, B J P Jones, T Katori, et al. “Testing of Cryogenic Photomultiplier Tubes for the MicroBooNE Experiment.” Journal of Instrumentation 8, no. 07 (July 23, 2013): T07005–T07005.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physicsen_US
dc.contributor.departmentMassachusetts Institute of Technology. Laboratory for Nuclear Scienceen_US
dc.contributor.mitauthorBugel, Leonard G.en_US
dc.contributor.mitauthorConrad, Janeten_US
dc.contributor.mitauthorIgnarra, Christinaen_US
dc.contributor.mitauthorJones, Benjamin James Poyneren_US
dc.contributor.mitauthorKatori, Teppeien_US
dc.contributor.mitauthorPrakash, A.en_US
dc.contributor.mitauthorToups, Matthewen_US
dc.relation.journalJournal of Instrumentationen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsBriese, T; Bugel, L; Conrad, J M; Fournier, M; Ignarra, C; Jones, B J P; Katori, T; Navarrete-Perez, R; Nienaber, P; McDonald, T; Musolf, B; Prakash, A; Shockley, E; Smidt, T; Swanson, K; Toups, Men_US
dc.identifier.orcidhttps://orcid.org/0000-0002-9429-9482
dc.identifier.orcidhttps://orcid.org/0000-0002-6393-0438
dc.identifier.orcidhttps://orcid.org/0000-0003-3837-3921
dc.identifier.orcidhttps://orcid.org/0000-0001-6243-1453
dspace.mitauthor.errortrue
mit.licenseOPEN_ACCESS_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record