The MIT Libraries is completing a major upgrade to DSpace@MIT. Starting May 5 2026, DSpace will remain functional, viewable, searchable, and downloadable, however, you will not be able to edit existing collections or add new material. We are aiming to have full functionality restored by May 18, 2026 but intermittent service interruptions may occur. Please email dspace-lib@mit.edu
with any questions. Thank you for your patience as we implement this important upgrade.
Unique Airflow Visualization Techniques for the Design and Validation of Above-Plenum Data Center CFD Models
| dc.contributor.author | Lloyd, Michael | |
| dc.contributor.author | Glicksman, Leon R. | |
| dc.date.accessioned | 2014-09-30T16:31:41Z | |
| dc.date.available | 2014-09-30T16:31:41Z | |
| dc.date.issued | 2011-05 | |
| dc.identifier.issn | 0001-2505 | |
| dc.identifier.uri | http://hdl.handle.net/1721.1/90482 | |
| dc.description.abstract | One cause for the substantial amount of energy used for data center cooling is poor airflow effects such as hot-aisle to cold-aisle air recirculation. To correct these and to investigate innovative designs that will notably increase efficiency requires a robust, well-verified computational fluid dynamics (CFD) model. Most above-plenum data center CFD models are only validated using temperature data. Although a temperature-only validation method can be useful, it does not confirm that the airflow patterns predicted by the CFD model are accurate. Since the airflow patterns above a raised-floor plenum should be confidently understood before they can be optimized, it is necessary to adopt a validation method that offers more than just a comparison of temperature data. This paper summarizes the unique validation process of a CFD model for a small data center test cell located in Cambridge, Massachusetts. The validation method features point velocity and temperature measurements and the use of small neutrally-buoyant bubbles to visualize the airflow patterns above a raised-floor plenum. The data center test cell was designed to emulate a standard hot-aisle and cold-aisle airflow configuration. The airflow visualization revealed that each perforated tile had a substantial non-uniform air velocity distribution leading to an unexpected three-dimensional flow pattern above the racks. When this surprising reality was properly accounted for in the CFD boundary conditions, good agreement was found with the observed airflow patterns. It is the purpose of this paper to show the difficulties and value of utilizing more robust validation techniques for data center CFD models. | en_US |
| dc.language.iso | en_US | |
| dc.publisher | American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) | en_US |
| dc.relation.isversionof | http://connection.ebscohost.com/c/articles/67359312/unique-airflow-visualization-techniques-design-validation-above-plenum-data-center-cfd-models | en_US |
| dc.rights | Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. | en_US |
| dc.source | Ebsco | en_US |
| dc.title | Unique Airflow Visualization Techniques for the Design and Validation of Above-Plenum Data Center CFD Models | en_US |
| dc.type | Article | en_US |
| dc.identifier.citation | Lloyd, Michael, and Leon Glicksman. "Unique Airflow Visualization Techniques for the Design and Validation of Above-Plenum Data Center CFD Models." ASHRAE Transactions, Vol. 117, Issue 1 (2011). © American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Building Technology Group | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Architecture | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Mechanical Engineering | en_US |
| dc.contributor.mitauthor | Lloyd, Michael | en_US |
| dc.contributor.mitauthor | Glicksman, Leon R. | en_US |
| dc.relation.journal | ASHRAE Transactions | en_US |
| dc.eprint.version | Final published version | en_US |
| dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
| eprint.status | http://purl.org/eprint/status/PeerReviewed | en_US |
| dspace.orderedauthors | Lloyd, Michael; Glicksman, Leon | en_US |
| mit.license | PUBLISHER_POLICY | en_US |
| mit.metadata.status | Complete |