Show simple item record

dc.contributor.authorStoeck, Christian T.
dc.contributor.authorKalinowska, Aleksandra
dc.contributor.authorvon Deuster, Constantin
dc.contributor.authorHarmer, Jack
dc.contributor.authorChan, Rachel W.
dc.contributor.authorNiemann, Markus
dc.contributor.authorManka, Robert
dc.contributor.authorAtkinson, David
dc.contributor.authorSosnovik, David E.
dc.contributor.authorMekkaoui, Choukri
dc.contributor.authorKozerke, Sebastian
dc.date.accessioned2014-10-20T18:20:24Z
dc.date.available2014-10-20T18:20:24Z
dc.date.issued2014-09
dc.date.submitted2014-05
dc.identifier.issn1932-6203
dc.identifier.urihttp://hdl.handle.net/1721.1/91002
dc.description.abstractPurpose: In this work we present a dual-phase diffusion tensor imaging (DTI) technique that incorporates a correction scheme for the cardiac material strain, based on 3D myocardial tagging. Methods: In vivo dual-phase cardiac DTI with a stimulated echo approach and 3D tagging was performed in 10 healthy volunteers. The time course of material strain was estimated from the tagging data and used to correct for strain effects in the diffusion weighted acquisition. Mean diffusivity, fractional anisotropy, helix, transverse and sheet angles were calculated and compared between systole and diastole, with and without strain correction. Data acquired at the systolic sweet spot, where the effects of strain are eliminated, served as a reference. Results: The impact of strain correction on helix angle was small. However, large differences were observed in the transverse and sheet angle values, with and without strain correction. The standard deviation of systolic transverse angles was significantly reduced from 35.9±3.9° to 27.8°±3.5° (p<0.001) upon strain-correction indicating more coherent fiber tracks after correction. Myocyte aggregate structure was aligned more longitudinally in systole compared to diastole as reflected by an increased transmural range of helix angles (71.8°±3.9° systole vs. 55.6°±5.6°, p<0.001 diastole). While diastolic sheet angle histograms had dominant counts at high sheet angle values, systolic histograms showed lower sheet angle values indicating a reorientation of myocyte sheets during contraction. Conclusion: An approach for dual-phase cardiac DTI with correction for material strain has been successfully implemented. This technique allows assessing dynamic changes in myofiber architecture between systole and diastole, and emphasizes the need for strain correction when sheet architecture in the heart is imaged with a stimulated echo approach.en_US
dc.description.sponsorshipNational Institutes of Health (U.S.) (5R01HL112831)en_US
dc.language.isoen_US
dc.publisherPublic Library of Scienceen_US
dc.relation.isversionofhttp://dx.doi.org/10.1371/journal.pone.0107159en_US
dc.rightsCreative Commons Attributionen_US
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en_US
dc.sourcePublic Library of Scienceen_US
dc.titleDual-Phase Cardiac Diffusion Tensor Imaging with Strain Correctionen_US
dc.typeArticleen_US
dc.identifier.citationStoeck, Christian T., Aleksandra Kalinowska, Constantin von Deuster, Jack Harmer, Rachel W. Chan, Markus Niemann, Robert Manka, et al. “Dual-Phase Cardiac Diffusion Tensor Imaging with Strain Correction.” Edited by Alexander Leemans. PLoS ONE 9, no. 9 (September 5, 2014): e107159.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Center for Biomedical Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorKalinowska, Aleksandraen_US
dc.relation.journalPLoS ONEen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsStoeck, Christian T.; Kalinowska, Aleksandra; von Deuster, Constantin; Harmer, Jack; Chan, Rachel W.; Niemann, Markus; Manka, Robert; Atkinson, David; Sosnovik, David E.; Mekkaoui, Choukri; Kozerke, Sebastianen_US
mit.licensePUBLISHER_CCen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record