Show simple item record

dc.contributor.authorSung, Yongjin
dc.contributor.authorSegars, W. Paul
dc.contributor.authorPan, Adam
dc.contributor.authorAndo, Masami
dc.contributor.authorSheppard, Colin J. R.
dc.contributor.authorGupta, Rajiv
dc.date.accessioned2015-09-10T16:19:21Z
dc.date.available2015-09-10T16:19:21Z
dc.date.issued2015-07
dc.date.submitted2015-03
dc.identifier.issn2045-2322
dc.identifier.urihttp://hdl.handle.net/1721.1/98439
dc.description.abstractX-ray phase-contrast imaging (XPCI) can dramatically improve soft tissue contrast in X-ray medical imaging. Despite worldwide efforts to develop novel XPCI systems, a numerical framework to rigorously predict the performance of a clinical XPCI system at a human scale is not yet available. We have developed such a tool by combining a numerical anthropomorphic phantom defined with non-uniform rational B-splines (NURBS) and a wave optics-based simulator that can accurately capture the phase-contrast signal from a human-scaled numerical phantom. Using a synchrotron-based, high-performance XPCI system, we provide qualitative comparison between simulated and experimental images. Our tool can be used to simulate the performance of XPCI on various disease entities and compare proposed XPCI systems in an unbiased manner.en_US
dc.description.sponsorshipUnited States. Defense Advanced Research Projects Agency. AXiS Program (Grant N66001-11-4204, P.R. 1300217190)en_US
dc.description.sponsorshipJapan. Ministry of Education, Culture, Sports, Science and Technology (Grant-in-Aid for Scientific Research 18206011)en_US
dc.language.isoen_US
dc.publisherNature Publishing Groupen_US
dc.relation.isversionofhttp://dx.doi.org/10.1038/srep12011en_US
dc.rightsCreative Commons Attributionen_US
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/en_US
dc.sourceNature Publishing Groupen_US
dc.titleRealistic wave-optics simulation of X-ray phase-contrast imaging at a human scaleen_US
dc.typeArticleen_US
dc.identifier.citationSung, Yongjin, W. Paul Segars, Adam Pan, Masami Ando, Colin J. R. Sheppard, and Rajiv Gupta. “Realistic Wave-Optics Simulation of X-Ray Phase-Contrast Imaging at a Human Scale.” Scientific Reports 5 (July 14, 2015): 12011.en_US
dc.contributor.departmentHarvard University--MIT Division of Health Sciences and Technologyen_US
dc.contributor.mitauthorPan, Adamen_US
dc.relation.journalScientific Reportsen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsSung, Yongjin; Segars, W. Paul; Pan, Adam; Ando, Masami; Sheppard, Colin J. R.; Gupta, Rajiven_US
dc.identifier.orcidhttps://orcid.org/0000-0002-5770-1241
mit.licensePUBLISHER_CCen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record