A Numerical Solution Algorithm for a Heat and Mass Transfer Model of a Desalination System Based on Packed-Bed Humidification and Bubble Column Dehumidification

Author(s)
Cheaib, Farah K.; Chehayeb, Karim Malek; Lienhard, John H
Thumbnail
DownloadMain article (768.7Kb)
OPEN_ACCESS_POLICY

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
The humidification-dehumidification (HDH) desalination system can be advantageous in small-scale, off-grid applications. The main drawback of this technology has been its low energy efficiency, which results in high water production costs. Previous studies have approached this issue through thermodynamic balancing of the system; however, most theoretical work on the balancing of HDH has followed a fixed-effectiveness approach that does not explicitly consider transport processes in the components. Fixing the effectiveness of the heat and mass exchangers allows them to be modeled without explicitly sizing the components and gives insight on how the cycle design can be improved. However, linking the findings of fixed-effectiveness models to actual systems can be challenging, as the performance of the components depends mainly on the available surface areas and the flow rates of the air and water streams. In this study, we present a robust numerical solution algorithm for a heat and mass tranfer model of a complete humidification-dehumidification system consisting of a packed-bed humidifier and a multi-tray bubble column dehumidifier. We look at the effect of varying the water-to-air mass flow rate ratio on the energy efficiency of the system, and we compare the results to those reached following a fixed-effectiveness approach. In addition, we study the effect of the top and bottom temperatures on the performance of the system. We recommended the implementation a control system that varies the mass flow rate ratio in order to keep the system balanced in off-design conditions, especially with varying top temperature.
Date issued
2014-08
URI
http://hdl.handle.net/1721.1/99725
Department
Massachusetts Institute of Technology. Abdul Latif Jameel World Water & Food Security Lab; Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
Proceedings of the 15th International Heat Transfer Conference
Publisher
Begell House Inc.
Citation
Chehayeb, Karim, Farah K. Cheaib, and John H. Lienhard. “A Numerical Solution Algorithm for a Heat and Mass Transfer Model of a Desalination System Based on Packed-Bed Humidification and Bubble Column Dehumidification.” Proceedings of the 15th International Heat Transfer Conference (2014).
Version: Author's final manuscript
ISBN
978-1-56700-421-2

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.