Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger

Author(s)
Habib, M. A.; Said, S. A.; Khalifa, A.; Nemitallah, M. A.; Ayinde, T.
Thumbnail
Download13369_2014_1384_ReferencePDF.pdf (799.8Kb)
PUBLISHER_POLICY

Publisher Policy

Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Terms of use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Metadata
Show full item record
Abstract
Flow maldistribution in heat exchanger tubes can significantly affect its performance. In this work, 16 tubes are connected between the inlet and the exit headers forming the heat exchanger. The feed nozzle is connected to the inlet header, and its connection point can be altered. The influences of inlet flow Reynolds number, nozzle diameter, number of nozzles and nozzle location on the flow maldistribution are experimentally investigated. Water is chosen to be the working fluid inside the heat exchanger set of tubes. At lower flow rates, the results showed that the flow Reynolds number has a significant effect on the flow maldistribution inside the heat exchanger set of tubes; however, at higher flow rates, this effect was insignificant. Locating the nozzle at the center of the inlet header resulted in about 25–30% reduction in the standard deviation (STD) of the flow rate inside the tubes. Increasing the number of inlet nozzles resulted in an insignificant effect on the flow maldistribution. Increasing the nozzle diameter resulted in increased STD of the flow rate distribution among the tubes and pressure drop across the tubes at the considered heat exchanger geometry and water flow rate.
Date issued
2014-10
URI
http://hdl.handle.net/1721.1/103147
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Journal
Arabian Journal for Science and Engineering
Publisher
Springer Berlin Heidelberg
Citation
Habib, M. A., S. A. Said, A. Khalifa, M. A. Nemitallah, and T. Ayinde. “Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger.” Arabian Journal for Science and Engineering 39, no. 11 (October 4, 2014): 8187–8198.
Version: Author's final manuscript
ISSN
1319-8025
2191-4281

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.