dc.description.abstractFlow maldistribution in heat exchanger tubes can significantly affect its performance. In this work, 16 tubes are connected between the inlet and the exit headers forming the heat exchanger. The feed nozzle is connected to the inlet header, and its connection point can be altered. The influences of inlet flow Reynolds number, nozzle diameter, number of nozzles and nozzle location on the flow maldistribution are experimentally investigated. Water is chosen to be the working fluid inside the heat exchanger set of tubes. At lower flow rates, the results showed that the flow Reynolds number has a significant effect on the flow maldistribution inside the heat exchanger set of tubes; however, at higher flow rates, this effect was insignificant. Locating the nozzle at the center of the inlet header resulted in about 25–30% reduction in the standard deviation (STD) of the flow rate inside the tubes. Increasing the number of inlet nozzles resulted in an insignificant effect on the flow maldistribution. Increasing the nozzle diameter resulted in increased STD of the flow rate distribution among the tubes and pressure drop across the tubes at the considered heat exchanger geometry and water flow rate.en_US
dc.description.sponsorshipKing Fahd University of Petroleum and Minerals (Project No. IN090016)en_US
dc.publisherSpringer Berlin Heidelbergen_US
dc.relation.isversionofhttp://dx.doi.org/10.1007/s13369-014-1384-0en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSpringer Berlin Heidelbergen_US
dc.titleExperimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchangeren_US
dc.typeArticleen_US
dc.identifier.citationHabib, M. A., S. A. Said, A. Khalifa, M. A. Nemitallah, and T. Ayinde. “Experimental Investigation of the Flow Maldistribution Inside an Air-Cooled Heat Exchanger.” Arabian Journal for Science and Engineering 39, no. 11 (October 4, 2014): 8187–8198.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.mitauthorNemitallah, M. A.en_US
dc.relation.journalArabian Journal for Science and Engineeringen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2016-05-23T12:12:39Z
dc.language.rfc3066en
dc.rights.holderKing Fahd University of Petroleum and Minerals
dspace.orderedauthorsHabib, M. A.; Said, S. A.; Khalifa, A.; Nemitallah, M. A.; Ayinde, T.en_US
dspace.embargo.termsNen
mit.licensePUBLISHER_POLICYen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record