Failure of Fractional Horsepower Ventilation Fan Motors

Author(s)
Haslam, Bryan; Galler, Donald; Eagar, Thomas W
Thumbnail
Download10694_2018_720_ReferencePDF.pdf (12.02Mb)
Open Access Policy

Open Access Policy

Creative Commons Attribution-Noncommercial-Share Alike

Terms of use
Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/
Metadata
Show full item record
Abstract
Abstract Fractional horsepower motors are used to power exhaust fans such as those found in bathrooms and oven hoods. There was an increase in fires attributed to these motors shortly after the year 2000. Still, many argue that these motors cannot cause fires because they contain a thermal cutoff (TCO) unit that shuts off electrical current when the TCO reaches a specific temperature. In this paper we describe an unsafe failure mode that can occur after extended use. As fans age, the bearings wear out, resulting in heating of the coil wires. Excessive heating results in break down of the wire insulation, which can lead to a short between wires and create an autotransformer configuration. An autotransformer can support high current in only part of the wiring, resulting in resistive heating sufficient for ignition. With the low thermal conductivity of the coil ( $$0.0162\,W/(\hbox {cm}\,{^{\circ }}\hbox {C})$$ 0.0162 W / ( cm ∘ C ) ) and the poor performance of the TCO (no cutoff up to $$260{^{\circ }}\hbox {C}$$ 260 ∘ C ), a large temperature gradient is possible. The gradient allows for ignition in one part of the motor without activating the TCO. We experimentally validated the proposed mechanism in an isolated motor and a complete fan assembly resulting in ignition after 18 s and 23 s. The assembled fan burned for more than 6 minutes before we extinguished the flames for safety reasons. Our results are consistent with field results from actual fires.
Date issued
2018-04-09
URI
https://hdl.handle.net/1721.1/131912
Department
Massachusetts Institute of Technology. Department of Materials Science and Engineering
Publisher
Springer US

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.