Show simple item record

dc.contributor.authorDenniston, AW
dc.contributor.authorSegarra, Efrain Patrick
dc.contributor.authorSchmidt, Axel
dc.contributor.authorBeck, Arie
dc.contributor.authorBeck, S. May-Tal
dc.contributor.authorCruz Torres, Reynier
dc.contributor.authorHauenstein, F.
dc.contributor.authorHrnjic, A.
dc.contributor.authorKutz, Tyler
dc.contributor.authorNambrath, Anjali
dc.contributor.authorPybus, J. R.
dc.contributor.authorToldeo, P.
dc.contributor.authorHen, Or
dc.contributor.authorWeinstein, L.B.
dc.contributor.authorOlivenboim, M.
dc.contributor.authorPiazetzky, E.
dc.contributor.authorKorover, I.
dc.date.accessioned2022-08-03T16:25:55Z
dc.date.available2021-09-20T18:22:33Z
dc.date.available2022-08-03T16:25:55Z
dc.date.issued2020
dc.identifier.urihttps://hdl.handle.net/1721.1/132466.2
dc.description.abstract© 2020 Elsevier B.V. A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors.en_US
dc.language.isoen
dc.publisherElsevier BVen_US
dc.relation.isversionof10.1016/j.nima.2020.164177en_US
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivs Licenseen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/en_US
dc.sourcearXiven_US
dc.titleLaser calibration system for time of flight scintillator arraysen_US
dc.typeArticleen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physicsen_US
dc.contributor.departmentMassachusetts Institute of Technology. Laboratory for Nuclear Scienceen_US
dc.relation.journalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2020-10-27T17:45:06Z
dspace.orderedauthorsDenniston, A; Segarra, EP; Olivenboim, M; Nambrath, A; Schmidt, A; Beck, A; Cruz-Torres, R; Hauenstein, F; Hrnjic, A; Kutz, T; May-Tal Beck, S; Pybus, JR; Toledo, P; Hen, O; Weinstein, LB; Piasetzky, E; Korover, Ien_US
dspace.date.submission2020-10-27T17:45:24Z
mit.journal.volume973en_US
mit.licensePUBLISHER_CC
mit.metadata.statusPublication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

VersionItemDateSummary

*Selected version