Notice
This is not the latest version of this item. The latest version can be found at:https://dspace.mit.edu/handle/1721.1/132466.2
Laser calibration system for time of flight scintillator arrays
| dc.contributor.author | Denniston, A | |
| dc.contributor.author | Segarra, EP | |
| dc.contributor.author | Olivenboim, M | |
| dc.contributor.author | Nambrath, A | |
| dc.contributor.author | Schmidt, A | |
| dc.contributor.author | Beck, A | |
| dc.contributor.author | Cruz-Torres, R | |
| dc.contributor.author | Hauenstein, F | |
| dc.contributor.author | Hrnjic, A | |
| dc.contributor.author | Kutz, T | |
| dc.contributor.author | May-Tal Beck, S | |
| dc.contributor.author | Pybus, JR | |
| dc.contributor.author | Toledo, P | |
| dc.contributor.author | Hen, O | |
| dc.contributor.author | Weinstein, LB | |
| dc.contributor.author | Piasetzky, E | |
| dc.contributor.author | Korover, I | |
| dc.date.accessioned | 2021-09-20T18:22:33Z | |
| dc.date.available | 2021-09-20T18:22:33Z | |
| dc.identifier.uri | https://hdl.handle.net/1721.1/132466 | |
| dc.description.abstract | © 2020 Elsevier B.V. A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors. | en_US |
| dc.language.iso | en | |
| dc.publisher | Elsevier BV | en_US |
| dc.relation.isversionof | 10.1016/j.nima.2020.164177 | en_US |
| dc.rights | Creative Commons Attribution-NonCommercial-NoDerivs License | en_US |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | en_US |
| dc.source | arXiv | en_US |
| dc.title | Laser calibration system for time of flight scintillator arrays | en_US |
| dc.type | Article | en_US |
| dc.relation.journal | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en_US |
| dc.eprint.version | Author's final manuscript | en_US |
| dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
| eprint.status | http://purl.org/eprint/status/PeerReviewed | en_US |
| dc.date.updated | 2020-10-27T17:45:06Z | |
| dspace.orderedauthors | Denniston, A; Segarra, EP; Olivenboim, M; Nambrath, A; Schmidt, A; Beck, A; Cruz-Torres, R; Hauenstein, F; Hrnjic, A; Kutz, T; May-Tal Beck, S; Pybus, JR; Toledo, P; Hen, O; Weinstein, LB; Piasetzky, E; Korover, I | en_US |
| dspace.date.submission | 2020-10-27T17:45:24Z | |
| mit.journal.volume | 973 | en_US |
| mit.license | PUBLISHER_CC | |
| mit.metadata.status | Authority Work and Publication Information Needed |
