Acute Stent-Induced Endothelial Denudation: Biomechanical Predictors of Vascular Injury

Author(s)
Conway, Claire; Nezami, Farhad R.; Rogers, Campbell; Groothuis, Adam; Squire, James C.; Edelman, Elazer R.; ... Show more Show less
Thumbnail
Downloadfcvm-08-733605.pdf (1.700Mb)
Publisher with Creative Commons License

Publisher with Creative Commons License

Creative Commons Attribution

Terms of use
Creative Commons Attribution 4.0 International license https://creativecommons.org/licenses/by/4.0/
Metadata
Show full item record
Abstract
<jats:p>Recent concern for local drug delivery and withdrawal of the first Food and Drug Administration-approved bioresorbable scaffold emphasizes the need to optimize the relationships between stent design and drug release with imposed arterial injury and observed pharmacodynamics. In this study, we examine the hypothesis that vascular injury is predictable from stent design and that the expanding force of stent deployment results in increased circumferential stress in the arterial tissue, which may explain acute injury poststent deployment. Using both numerical simulations and <jats:italic>ex vivo</jats:italic> experiments on three different stent designs (slotted tube, corrugated ring, and delta wing), arterial injury due to device deployment was examined. Furthermore, using numerical simulations, the consequence of changing stent strut radial thickness on arterial wall shear stress and arterial circumferential stress distributions was examined. Regions with predicted arterial circumferential stress exceeding a threshold of 49.5 kPa compared favorably with observed <jats:italic>ex vivo</jats:italic> endothelial denudation for the three considered stent designs. In addition, increasing strut thickness was predicted to result in more areas of denudation and larger areas exposed to low wall shear stress. We conclude that the acute arterial injury, observed immediately following stent expansion, is caused by high circumferential hoop stresses in the interstrut region, and denuded area profiles are dependent on unit cell geometric features. Such findings when coupled with where drugs move might explain the drug–device interactions.</jats:p>
Date issued
2021-10-15
URI
https://hdl.handle.net/1721.1/138497
Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Publisher
Frontiers Media SA
Citation
Conway, Claire, Nezami, Farhad R., Rogers, Campbell, Groothuis, Adam, Squire, James C. et al. 2021. "Acute Stent-Induced Endothelial Denudation: Biomechanical Predictors of Vascular Injury." 8.
Version: Final published version
ISSN
2297-055X

Collections
  • MIT Open Access Articles

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.