A Review of Corrosion under Insulation: A Critical Issue in the Oil and Gas Industry
Author(s)
Cao, Qing; Pojtanabuntoeng, Thunyaluk; Esmaily, Marco; Thomas, Sebastian; Brameld, Michael; Amer, Ayman; Birbilis, Nick; ... Show more Show less
Downloadmetals-12-00561-v2.pdf (2.730Mb)
Publisher with Creative Commons License
Publisher with Creative Commons License
Creative Commons Attribution
Terms of use
Metadata
Show full item recordAbstract
Corrosion under insulation (CUI) is defined as any form of external corrosion that occurs on the underlying metal beneath insulated equipment, due to water ingress through the insulation layer. This type of corrosion is frequently observed in oil and gas production, where insulated piping is prevalent, and has historically remained a predominant materials integrity issue. The prediction and direct visualisation of CUI are challenging tasks because of the coverage of the insulation layer(s) and any external jacketing or cladding. Several factors, including the local/ambient environment, system design, and the piping installation process, can influence how CUI initiates and propagates. In this review, CUI background, CUI monitoring, and CUI mitigation strategies are discussed.
Date issued
2022-03Department
Massachusetts Institute of Technology. Department of Materials Science and EngineeringJournal
Metals
Publisher
Multidisciplinary Digital Publishing Institute
Citation
Metals 12 (4): 561 (2022)
Version: Final published version