Show simple item record

dc.contributor.authorLee, Na E.
dc.contributor.authorHong, Ji H.
dc.contributor.authorLee, Seungmin
dc.contributor.authorYoo, Yong K.
dc.contributor.authorKim, Kang H.
dc.contributor.authorPark, Jeong S.
dc.contributor.authorKim, Cheonjung
dc.contributor.authorYoon, Junghyo
dc.contributor.authorYoon, Dae S.
dc.contributor.authorLee, Jeong H.
dc.date.accessioned2024-01-02T20:43:22Z
dc.date.available2024-01-02T20:43:22Z
dc.date.issued2023-09-21
dc.identifier.urihttps://hdl.handle.net/1721.1/153263
dc.description.abstractPoint-of-care testing using paper-based lateral flow assays (LFAs) has emerged as an attractive diagnostic platform. However, detecting small molecules such as cortisol using LFAs is challenging due to limited binding sites and weak signal generation. Here, we report the development of cortisol-specific aptamer-based probes and a paper-based origami preconcentrator (POP) to amplify the probe signal. The cortisol-specific aptamers were conjugated onto gold nanoparticles and hybridized with signal probes to create the cortisol-specific signal-on probe. POP, consisting of patterned layers with convergent wicking zones, induces electrokinetic preconcentration of the released signaling probes. By integrating cortisol-selective aptamer-based probes and POP, we accurately diagnosed cortisol levels within 30 min of signal probe incubation, followed by 10 min of preconcentration. Our sensor was able to detect cortisol levels in the range of 25–1000 ng/mL, with typical cortisol levels in plasma ranging from 40 to 250 ng/mL falling within this range. The successful detection of the wide range of cortisol samples using this approach highlights the potential of this platform as a point-of-care testing tool, particularly for lateral flow assay-based detection of small molecules like cortisol. Our approach offers a convenient and reliable method of cortisol level testing with a portable and accessible diagnosis device.en_US
dc.publisherThe Korean BioChip Society (KBCS)en_US
dc.relation.isversionofhttps://doi.org/10.1007/s13206-023-00119-xen_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.titleIntegration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detectionen_US
dc.typeArticleen_US
dc.identifier.citationLee, N.E., Hong, J.H., Lee, S. et al. Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection. BioChip J 17, 439–446 (2023).en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dc.date.updated2023-12-24T04:17:40Z
dc.language.rfc3066en
dc.rights.holderThe Korean BioChip Society
dc.embargo.date
dspace.date.submission2023-12-24T04:17:40Z
mit.licensePUBLISHER_POLICY
mit.metadata.statusAuthority Work and Publication Information Neededen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record