dc.contributor.author | Kim, Yang-Hyo | en_US |
dc.contributor.author | Tang, Wai Teng | en_US |
dc.contributor.author | So, Peter T. C. | en_US |
dc.contributor.author | Chung, Euiheon | en_US |
dc.contributor.author | Sheppard, Colin J. R. | en_US |
dc.date.accessioned | 2009-10-19T13:01:02Z | |
dc.date.available | 2009-10-19T13:01:02Z | |
dc.date.issued | 2009-07 | en_US |
dc.date.submitted | 2009-03 | en_US |
dc.identifier.uri | http://hdl.handle.net/1721.1/49438 | |
dc.description.abstract | The resolution of conventional SPR imaging has been limited by the diffraction nature of light. A wide-field extended-resolution optical imaging technique, standing-wave surface plasmon resonance fluorescence (SW-SPRF) microscopy, has been developed. Based on evanescent SPR standing waves, SW-SPRF provides lateral resolution approaching 100 nm and offers the advantages of significant signal enhancement and background noise reduction. SW-SPRF has the potential for sensitive biomolecular detection, nanoscale imaging, and lithographic applications. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Optical Society of America | en_US |
dc.relation.isversionof | http://dx.doi.org/10.1364/OL.34.002366 | en_US |
dc.rights | Creative Commons Attribution-Noncommercial-Share Alike | en_US |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/ | en_US |
dc.source | Euiheon Chung [ogong50@MIT.EDU] | en_US |
dc.title | Wide-field extended-resolution fluorescence microscopy with standing surface plasmon resonance waves | en_US |
dc.title.alternative | Wide-field extended-resolution fluorescence microscopy with standing surface-plasmon-resonance waves | en_US |
dc.type | Article | en_US |
dc.identifier.citation | Euiheon Chung, Yang-Hyo Kim, Wai Teng Tang, Colin J. R. Sheppard, and Peter T. C. So, "Wide-field extended-resolution fluorescence microscopy with standing surface-plasmon-resonance waves," Opt. Lett. 34, 2366-2368 (2009) | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Department of Biological Engineering | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Department of Mechanical Engineering | en_US |
dc.contributor.approver | So, Peter T.C. | en_US |
dc.contributor.mitauthor | Chung, Euiheon | en_US |
dc.contributor.mitauthor | Kim, Yang-Hyo | en_US |
dc.contributor.mitauthor | So, Peter T. C. | en_US |
dc.relation.journal | Optics Letters | en_US |
dc.eprint.version | Author's final manuscript | |
dc.type.uri | http://purl.org/eprint/type/SubmittedJournalArticle | en_US |
eprint.status | http://purl.org/eprint/status/PeerReviewed | en_US |
dspace.orderedauthors | Chung, Euiheon; Kim, Yang-Hyo; Tang, Wai Teng; Sheppard, Colin J.; So, Peter T. | en |
dc.identifier.orcid | https://orcid.org/0000-0002-3326-6927 | |
dc.identifier.orcid | https://orcid.org/0000-0003-4698-6488 | |
dc.identifier.orcid | https://orcid.org/0000-0001-5183-576X | |
mit.license | OPEN_ACCESS_POLICY | en_US |
mit.metadata.status | Complete | |