| dc.contributor.author | Brault, Norman D. | |
| dc.contributor.author | Jiang, Shaoyi | |
| dc.contributor.author | Von Muhlen, Marcio Goldani | |
| dc.contributor.author | Knudsen, Scott Michael | |
| dc.contributor.author | Manalis, Scott R. | |
| dc.date.accessioned | 2011-11-16T19:33:49Z | |
| dc.date.available | 2011-11-16T19:33:49Z | |
| dc.date.issued | 2010-02 | |
| dc.identifier.issn | 0003-2700 | |
| dc.identifier.issn | 1520-6882 | |
| dc.identifier.uri | http://hdl.handle.net/1721.1/67036 | |
| dc.description.abstract | Improved methods are needed for routine, inexpensive monitoring of biomarkers that could facilitate earlier detection and characterization of cancer. Suspended microchannel resonators (SMRs) are highly sensitive, batch-fabricated microcantilevers with embedded microchannels that can directly quantify adsorbed mass via changes in resonant frequency. As in other label-free detection methods, biomolecular measurements in complex media such as serum are challenging due to high background signals from nonspecific binding. In this report, we demonstrate that carboxybetaine-derived polymers developed to adsorb directly onto SMR SiO[subscript 2] surfaces act as ultralow fouling and functionalizable surface coatings. Coupled with a reference microcantilever, this approach enables detection of activated leukocyte cell adhesion molecule (ALCAM), a model cancer biomarker, in undiluted serum with a limit of detection of 10 ng/mL. | en_US |
| dc.description.sponsorship | National Cancer Institute (U.S.) (contract R01CA119402) | en_US |
| dc.description.sponsorship | SAIC-Frederick (contract 28XS119) | en_US |
| dc.description.sponsorship | National Institutes of Health (U.S.). Biotechnology Training Fellowship | en_US |
| dc.language.iso | en_US | |
| dc.publisher | American Chemical Society | en_US |
| dc.relation.isversionof | http://dx.doi.org/10.1021/ac9027356 | en_US |
| dc.rights | Creative Commons Attribution-Noncommercial-Share Alike 3.0 | en_US |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/ | en_US |
| dc.source | PubMed Central | en_US |
| dc.title | Label-free biomarker sensing in undiluted serum with suspended microchannel resonators | en_US |
| dc.type | Article | en_US |
| dc.identifier.citation | von Muhlen, Marcio G. et al. “Label-Free Biomarker Sensing in Undiluted Serum with Suspended Microchannel Resonators.” Analytical Chemistry 82 (2010): 1905-1910. Web. 16 Nov. 2011. © 2010 American Chemical Society | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Biological Engineering | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Mechanical Engineering | en_US |
| dc.contributor.approver | Manalis, Scott R. | |
| dc.contributor.mitauthor | Von Muhlen, Marcio Goldani | |
| dc.contributor.mitauthor | Knudsen, Scott Michael | |
| dc.contributor.mitauthor | Manalis, Scott R. | |
| dc.relation.journal | Analytical Chemistry | en_US |
| dc.eprint.version | Author's final manuscript | en_US |
| dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
| eprint.status | http://purl.org/eprint/status/PeerReviewed | en_US |
| dspace.orderedauthors | von Muhlen, Marcio G.; Brault, Norman D.; Knudsen, Scott M.; Jiang, Shaoyi; Manalis, Scott R. | en |
| dc.identifier.orcid | https://orcid.org/0000-0001-5223-9433 | |
| mit.license | OPEN_ACCESS_POLICY | en_US |
| mit.metadata.status | Complete | |