Show simple item record

dc.contributor.authorMavalvala, Nergis
dc.contributor.authorMavalvala, Nergis
dc.contributor.authorKawabe, K.
dc.contributor.authorFrolov, V. V.
dc.contributor.authorSmith, Nicolas de Mateo
dc.contributor.authorEvans, Matthew J
dc.contributor.authorWaldman, Samuel J.
dc.date.accessioned2013-01-24T20:03:55Z
dc.date.available2013-01-24T20:03:55Z
dc.date.issued2011-11
dc.date.submitted2011-08
dc.identifier.issn0146-9592
dc.identifier.issn1539-4794
dc.identifier.urihttp://hdl.handle.net/1721.1/76601
dc.description.abstractCritically coupled resonant optical cavities are often used as mode cleaners in optical systems to improve the signal-to-noise ratio (SNR) of a signal that is encoded as an amplitude modulation of a laser beam. Achieving the best SNR requires maintaining the alignment of the mode cleaner relative to the laser beam on which the signal is encoded. An automatic alignment system that is primarily sensitive to the carrier field component of the beam will not, in general, provide optimal SNR. We present an approach that modifies traditional dither alignment sensing by applying a large amplitude modulation on the signal field, thereby producing error signals that are sensitive to the signal sideband field alignment. When used in conjunction with alignment actuators, this approach can improve the detected SNR; we demonstrate a factor of 3 improvement in the SNR of a kilometer-scale detector of the Laser Interferometer Gravitational-Wave Observatory. This approach can be generalized to other types of alignment sensors.en_US
dc.description.sponsorshipNational Science Foundation (U.S.) (Cooperative Agreement PHY-0757058)en_US
dc.language.isoen_US
dc.publisherOptical Society of Americaen_US
dc.relation.isversionofhttp://dx.doi.org/10.1364/OL.36.004365en_US
dc.rightsCreative Commons Attribution-Noncommercial-Share Alike 3.0en_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/en_US
dc.sourcearXiven_US
dc.titleOptimal alignment sensing of a readout mode cleaner cavityen_US
dc.typeArticleen_US
dc.identifier.citationSmith-Lefebvre, N. et al. “Optimal Alignment Sensing of a Readout Mode Cleaner Cavity.” Optics Letters 36.22 (2011): 4365.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physicsen_US
dc.contributor.departmentLIGO (Observatory : Massachusetts Institute of Technology)en_US
dc.contributor.mitauthorSmith-Lefebvre, Nicolas
dc.contributor.mitauthorEvans, Matthew J.
dc.contributor.mitauthorWaldman, Sam
dc.contributor.mitauthorMavalvala, Nergis
dc.relation.journalOptics Lettersen_US
dc.eprint.versionAuthor's final manuscripten_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsSmith-Lefebvre, N.; Ballmer, S.; Evans, M.; Waldman, S.; Kawabe, K.; Frolov, V.; Mavalvala, N.en
dc.identifier.orcidhttps://orcid.org/0000-0003-0219-9706
dc.identifier.orcidhttps://orcid.org/0000-0001-8459-4499
mit.licenseOPEN_ACCESS_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record